Air sampling and analysis method to determine worker exposure levels to N -isopropyl- N ′-phenyl- p -phenylenediamine
Journal of Occupational Health · 2025
DOI: 10.1093/joccuh/uiaf059 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Occupational Health, 2025. Verfasst von Tomiko Tashiro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Kinki Osaka Safety and Health Service Center, Japan Industrial Safety and Health Association, 2-3-8 Tosabori, Nishi-Ku, Osaka 550-0001, Japan. Hauptthemen laut MEDLINE: Occupational Exposure, Air Pollutants, Occupational, Phenylenediamines, Environmental Monitoring. Die Arbeit nennt 7 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
This study aimed to develop a method for determining workers’ exposure concentrations to airborne N-isopropyl-N′-phenyl-p-phenylenediamine (IPPD).
Methods
A hydrophobic polytetrafluoroethylene (HPB PTFE) membrane filter was used as the sampling medium. IPPD was extracted from the HPB PTFE filter with acetonitrile, and its concentration in the extracted solution was determined using a high-performance liquid chromatograph equipped with a photodiode array detector. The validating method was performed using the following parameters: extraction and retention efficiency, storage stability, method quantitation limit, and reproducibility.
Results
The IPPD extraction efficiency from the spiked HPB PTFE filters was 96%-100%. The IPPD retention efficiencies on the HPB PTFE filters were 72%-99%, with relative standard deviations indicating the overall reproducibility of 0.9%-3.1%. IPPD on the HPB PTFE filter remained stable for at least 7 days at 4°C. The method quantitation limit was 12.5 μg/sample.
Conclusions
We successfully developed a method to measure workers’ exposure to airborne IPPD within the concentration range of 0.05-4 mg/m3, which will assist risk assessments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Kinki Osaka Safety and Health Service Center, Japan Industrial Safety and Health Association, 2-3-8 Tosabori, Nishi-Ku, Osaka 550-0001, Japan.
- Occupational Health Research and Development Center, Japan Industrial Safety and Health Association, 5-35-2 Shiba, Minato-Ku, Tokyo 108-0014, Japan.
- Kanto Regional Safety and Health Service Center, Japan Industrial Safety and Health Association, 1st fl, Sigma Bldg, 3-7-12 Shibaura, Minato-ku, Tokyo 108-0023, Japan.
- Laboratory of Environmental Toxicology and Carcinogenesis, School of Pharmacy, Nihon University, 7-7-1 Narashinodai, Funabashi, Chiba 274-8555, Japan.
- Department of Pathophysiological Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-minami, Higashi-Ku, Nagoya 461-8673, Japan.
- National Institute of Occupational Safety and Health, Nagao 6-21-1, Tama-Ku, Kawasaki 214-8585, Japan.
ORCID-Profile: Tomiko Tashiro, Akito Takeuchi, Kenta Ishii, Ai Yamada
Zitieren
APA
Tashiro, T., Takeuchi, A., Ishii, K., Yamada, A., Nishinoiri, O., Endo, G., & Ono-Ogasawara, M. (2025). Air sampling and analysis method to determine worker exposure levels to N -isopropyl- N ′-phenyl- p -phenylenediamine. Journal of Occupational Health. https://doi.org/10.1093/joccuh/uiaf059
Vancouver
Tashiro T, Takeuchi A, Ishii K, Yamada A, Nishinoiri O, Endo G, et al. Air sampling and analysis method to determine worker exposure levels to N -isopropyl- N ′-phenyl- p -phenylenediamine. Journal of Occupational Health. 2025. doi:10.1093/joccuh/uiaf059
BibTeX
@article{Tashiro2025,
author = {Tashiro, Tomiko and Takeuchi, Akito and Ishii, Kenta and Yamada, Ai and Nishinoiri, Osamu and Endo, Ginji and Ono-Ogasawara, Mariko},
title = {Air sampling and analysis method to determine worker exposure levels to N -isopropyl- N ′-phenyl- p -phenylenediamine},
journal = {Journal of Occupational Health},
year = {2025},
doi = {10.1093/joccuh/uiaf059}
}
EUVIMED