Fachartikel in der Zeitschrift Journal of Occupational Health, 2025. Verfasst von Akito Takeuchi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Kinki Osaka Safety and Health Service Center, Japan Industrial Safety and Health Association, 2-3-8 Tosabori, Nishi-Ku, Osaka 550-0001, Japan. Hauptthemen laut MEDLINE: Occupational Exposure, Organophosphates, Air Pollutants, Occupational, Inhalation Exposure. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to develop a personal exposure measurement method that concurrently determines both the inhalable fraction and vapor concentration of tri-n-butyl phosphate (TBP).

Methods

A personal sampler, the IFV Pro, equipped with a glass-fiber filter (GFF) and a Chromosorb 106 adsorption tube was used. Postsampling, TBP was extracted or desorbed separately from the GFF and Chromosorb 106 using dichloromethane containing tri-n-amyl phosphate as an internal standard. The solutions obtained were analyzed via gas chromatography with a flame ionization detector. The evaluation parameters for validating the method included extraction efficiency, desorption efficiency, retention efficiency, storage stability, method quantitation limit, and reproducibility.

Results

The extraction efficiency of TBP from the GFF ranged from 97% to 100%, whereas the desorption efficiency from Chromosorb 106 was between 98% and 102%. The retention efficiencies for TBP were 0% (not quantitative, <0.68 μg/sample) to 88% on the GFF, and 7% to 95% on Chromosorb 106, culminating in a total retention efficiency of 95%-98%. Relative SDs, indicative of reproducibility, ranged from 0.8% to 6.9%. Both TBP on the GFF and in the Chromosorb 106 tube maintained stability under refrigeration at 4°C for at least 7 days. The method quantitation limit was established at 6.00 μg/sample.

Conclusions

A method was established to measure both the inhalable fraction and vapor concentration of TBP across an air concentration range of 0.05 to 10 mg/m3. This method is potentially valuable for assessing TBP exposure levels in workers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Occupational ExposureOrganophosphatesAir Pollutants, OccupationalInhalation ExposureEnvironmental MonitoringHumansReproducibility of ResultsChromatography, Gas

Stichwörter der Autor:innen

air sampling methodgas chromatographypersonal exposure monitoringtri-n-butyl phosphateworkplace air

Substanzen

OrganophosphatesAir Pollutants, Occupationaltributyl phosphate

Autor:innen und Institutionen

  • Kinki Osaka Safety and Health Service Center, Japan Industrial Safety and Health Association, 2-3-8 Tosabori, Nishi-Ku, Osaka 550-0001, Japan.
  • Occupational Health Research and Development Center, Japan Industrial Safety and Health Association, 5-35-2 Shiba, Minato-Ku, Tokyo 108-0014, Japan.
  • Department of Pathophysiological Laboratory Sciences, Nagoya University Graduate School of Medicine, 1-1-20 Daiko-minami, Higashi-Ku, Nagoya 461-8673, Japan.
  • Kanto Regional Safety and Health Service Center, Japan Industrial Safety and Health Association, 1st fl, Sigma Bldg, 3-7-12 Shibaura, Minato-ku, Tokyo 108-0023, Japan.
  • Laboratory of Environmental Toxicology and Carcinogenesis, School of Pharmacy, Nihon University, 7-7-1 Narashinodai, Funabashi, Chiba 274-8555, Japan.
  • Research Center for Safety Science, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8601, Japan.

ORCID-Profile: Akito Takeuchi, Ai Yamada, Tomiko Tashiro, Kenta Ishii

Zitieren

APA

Takeuchi, A., Yamada, A., Tashiro, T., Inoue, M., Miyama, Y., Ishii, K., Yamamoto, S., Endo, Y., & Endo, G. (2025). A method for simultaneously determining both the inhalable fraction and vapor concentration to assess worker exposure to tri- n -butyl phosphate. Journal of Occupational Health. https://doi.org/10.1093/joccuh/uiaf063

Vancouver

Takeuchi A, Yamada A, Tashiro T, Inoue M, Miyama Y, Ishii K, et al. A method for simultaneously determining both the inhalable fraction and vapor concentration to assess worker exposure to tri- n -butyl phosphate. Journal of Occupational Health. 2025. doi:10.1093/joccuh/uiaf063

BibTeX
@article{Takeuchi2025,
  author = {Takeuchi, Akito and Yamada, Ai and Tashiro, Tomiko and Inoue, Maika and Miyama, Yuriko and Ishii, Kenta and Yamamoto, Shinobu and Endo, Yoko and Endo, Ginji},
  title = {A method for simultaneously determining both the inhalable fraction and vapor concentration to assess worker exposure to tri- n -butyl phosphate},
  journal = {Journal of Occupational Health},
  year = {2025},
  doi = {10.1093/joccuh/uiaf063}
}
Kostenlos starten →