Performance evaluation of a commercial LC–high-resolution-MS platform for untargeted whole blood analysis: comparison with immunoassay and LC–low-resolution-MS urine screening and targeted LC–MS/MS whole blood quantification
Journal of Analytical Toxicology · 04.06.2026 · 50 (6)
DOI: 10.1093/jat/bkag050 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Analytical Toxicology, online erschienen am 16.06.2026. Verfasst von Annina Bovens und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, CH-8057, Switzerland. Hauptthemen laut MEDLINE: Substance Abuse Detection, Illicit Drugs. Die Arbeit nennt 34 Literaturangaben.
Abstract (Originalsprache)
In forensic toxicology (FT), drug of abuse (DoA) screening is essential yet challenging. This study presents a vendor-based, high-resolution (HR) LC–MS/MS blood screening method implemented without in‑house optimization, in comparison to immunoassay-based and low-resolution (LR) urine screening approaches simultaneous to (semi)quantification. The HR-method allows detection of more than 3000 analytes, including DoAs, drugs and suspected new psychoactive substances (NPS). Following protein precipitation, analytes qualitatively identified in 500 authentic whole-blood samples using the HR-method were qualitatively compared with results from the immunoassay and LR urine screening. Additionally, 82 common DoAs and drugs were (semi)quantitatively validated according to ANSI and GTFCh guidelines and quantitative performance was assessed against a fully validated targeted LC–MS/MS method (MRM mode). In total, the HR-method detected 819 (83%) of the 994 analytes identified by the LR urine screening. Substances not captured by the HR approach typically showed concentrations below the identification limit and/or were of negligible relevance in FT. The HR blood screening detected 66% of all cases positive for THC and/or its metabolites, whereas the LR urine screening failed to detect these compounds entirely. Incorporation of the HighResNPS® database enabled the tentative identification of 14 NPS. Seventy-four (90%) of the 82 DoAs demonstrated accuracy within ± 30%, precision (CV) ≤ 30% and quantitative results of 100 authentic cases were consistent with those from the targeted LC–MS/MS method which is generally considered the gold standard for quantification. Overall, the HR blood screening is superior to the LR urine screening for most analyte classes, enabling simultaneous detection of DoAs, their metabolites and NPS. The semi-quantitative validation of 74 drugs and the quantitative comparison confirmed the method’s reliability in distinguishing between subtherapeutic, therapeutic and toxic concentrations without the need for drug class-specific optimization, thereby saving time, effort and costs. This untargeted approach combines screening with (semi)quantification while supporting routine workflows, research applications and retrospective analysis of new emerging substances.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Forensic Pharmacology and Toxicology, Zurich Institute of Forensic Medicine, University of Zurich, Zurich, CH-8057, Switzerland.
ORCID-Profile: Annina Bovens, Lana Brockbals, Thomas Kraemer, Andrea E Steuer
Zitieren
APA
Bovens, A., Brockbals, L., Kraemer, T., & Steuer, A. E. (2026). Performance evaluation of a commercial LC–high-resolution-MS platform for untargeted whole blood analysis: comparison with immunoassay and LC–low-resolution-MS urine screening and targeted LC–MS/MS whole blood quantification. Journal of Analytical Toxicology, 50(6). https://doi.org/10.1093/jat/bkag050
Vancouver
Bovens A, Brockbals L, Kraemer T, Steuer AE. Performance evaluation of a commercial LC–high-resolution-MS platform for untargeted whole blood analysis: comparison with immunoassay and LC–low-resolution-MS urine screening and targeted LC–MS/MS whole blood quantification. Journal of Analytical Toxicology. 2026;50(6). doi:10.1093/jat/bkag050
BibTeX
@article{Bovens2026,
author = {Bovens, Annina and Brockbals, Lana and Kraemer, Thomas and Steuer, Andrea E},
title = {Performance evaluation of a commercial LC–high-resolution-MS platform for untargeted whole blood analysis: comparison with immunoassay and LC–low-resolution-MS urine screening and targeted LC–MS/MS whole blood quantification},
journal = {Journal of Analytical Toxicology},
year = {2026},
volume = {50},
number = {6},
doi = {10.1093/jat/bkag050}
}
EUVIMED