EUVIMEDEUVIMED entdecken
Validierungsstudie

A validated dilute-and-shoot LC–MS-MS urine screening for the analysis of 95 illicit drugs and medicines: Insights from clinical and forensic Brazilian cases

Bruno Pereira Dos Santos iD, Letícia Birk, Patrícia Schwarz, Viviane Cristina Sebben, Ângela Malysz Sgaravatti, Giovanna Cristiano de Gouveia, Adriana Ubirajara Silva Petry, Francisco Paz de Menezes, Alexsandro Pinto Gonzaga, Paula Flores Schlickmann, Marcelo Dutra Arbo, Tiago Franco de Oliveira iD und 1 weitere

Journal of Analytical Toxicology · 11.06.2024 · 48 (5) · 314-331

DOI: 10.1093/jat/bkae005 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Analytical Toxicology, online erschienen am 08.02.2024. Verfasst von Bruno Pereira Dos Santos und 12 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program in Health Sciences, Federal University of Health Sciences of Porto Alegre, Porto Alegre, RS 90050-170, Brazil. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Illicit Drugs, Substance Abuse Detection, Forensic Toxicology. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 68 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Urine toxicological analysis is a relevant tool in both clinical and forensic scenarios, enabling the diagnosis of acute poisonings, elucidation of deaths, verification of substance use in the workplace and identification of drug-facilitated crimes. For these analyses, the dilute-and-shoot technique associated with liquid chromatography coupled with tandem mass spectrometry (LC–MS-MS) is a promising alternative since it has demonstrated satisfactory results and broad applicability. This study developed and validated a comprehensive LC–MS-MS screening method to analyze 95 illicit drugs and medicines in urine samples and application to clinical and forensic Brazilian cases. The dilute-and-shoot protocol was defined through multivariate optimization studies and was set using 100 µL of sample and 300 µL of solvent. The total chromatographic run time was 7.5 min. The method was validated following the recommendations of the ANSI/ASB Standard 036 Guideline. The lower limits of quantification varied from 20 to 100 ng/mL. Within-run and between-run precision coefficient of variations% were <20%, and bias was within ± 20%. Only 4 of the 95 analytes presented significant ionization suppression or enhancement (>25%). As proof of applicability, 839 urine samples from in vivo and postmortem cases were analyzed. In total, 90.9% of the analyzed samples were positive for at least one substance, and 78 of the 95 analytes were detected. The most prevalent substances were lidocaine (40.2%), acetaminophen (38.0%) and benzoylecgonine (31.5%). The developed method proved to be an efficient and simplified alternative for analyzing 95 therapeutic and illicit drugs in urine samples. Additionally, the results obtained from sample analysis are essential for understanding the profile of Brazilian substance use, serving as a valuable database for the promotion of health and safety public policies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryIllicit DrugsSubstance Abuse DetectionForensic ToxicologyHumansBrazilChromatography, LiquidReproducibility of ResultsLimit of DetectionLiquid Chromatography-Mass Spectrometry

Substanzen

Illicit Drugs

Autor:innen und Institutionen

  • Graduate Program in Health Sciences, Federal University of Health Sciences of Porto Alegre, Porto Alegre, RS 90050-170, Brazil.
  • Faculty of Pharmacy, Federal University of Rio Grande do Sul, Porto Alegre, RS 90010-150, Brazil.
  • Toxicological Information Center of Rio Grande do Sul, Porto Alegre, RS 90610-000, Brazil.
  • General Institute of Expertise of Rio Grande do Sul, Porto Alegre, RS 90230-010, Brazil.
  • Graduate Program in Pathology, Federal University of Health Sciences of Porto Alegre, Porto Alegre, RS 90050-170, Brazil.
  • Division of Postmortem Inspection, Associação Hospitalar Vila Nova, Porto Alegre, RS 91750-040, Brazil.

ORCID-Profile: Bruno Pereira Dos Santos, Tiago Franco de Oliveira, Sarah Eller

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Fundação de Amparo à Pesquisa do Estado do Rio Grande do Sul

Zitieren

APA

Dos Santos, B. P., Birk, L., Schwarz, P., Sebben, V. C., Sgaravatti, Â. M., de Gouveia, G. C., Silva Petry, A. U., de Menezes, F. P., Gonzaga, A. P., Schlickmann, P. F., Arbo, M. D., de Oliveira, T. F., & Eller, S. (2024). A validated dilute-and-shoot LC–MS-MS urine screening for the analysis of 95 illicit drugs and medicines: Insights from clinical and forensic Brazilian cases. Journal of Analytical Toxicology, 48(5), 314-331. https://doi.org/10.1093/jat/bkae005

Vancouver

Dos Santos BP, Birk L, Schwarz P, Sebben VC, Sgaravatti ÂM, de Gouveia GC, et al. A validated dilute-and-shoot LC–MS-MS urine screening for the analysis of 95 illicit drugs and medicines: Insights from clinical and forensic Brazilian cases. Journal of Analytical Toxicology. 2024;48(5):314-331. doi:10.1093/jat/bkae005

BibTeX
@article{DosSantos2024,
  author = {Dos Santos, Bruno Pereira and Birk, Letícia and Schwarz, Patrícia and Sebben, Viviane Cristina and Sgaravatti, Ângela Malysz and de Gouveia, Giovanna Cristiano and Silva Petry, Adriana Ubirajara and de Menezes, Francisco Paz and Gonzaga, Alexsandro Pinto and Schlickmann, Paula Flores and Arbo, Marcelo Dutra and de Oliveira, Tiago Franco and Eller, Sarah},
  title = {A validated dilute-and-shoot LC–MS-MS urine screening for the analysis of 95 illicit drugs and medicines: Insights from clinical and forensic Brazilian cases},
  journal = {Journal of Analytical Toxicology},
  year = {2024},
  volume = {48},
  number = {5},
  pages = {314--331},
  doi = {10.1093/jat/bkae005}
}
Kostenlos starten →