EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Evaluation of the surface characteristics and antibacterial properties of Titanium dioxide nanotube and methacryloyloxyethylphosphorylcholine (MPC) coated orthodontic brackets-a comparative invitro study

Madhura Rao, M V Ashith, Ethel Suman, Arun M Isloor, Neetha J Shetty, Srikant Natarajan

Clinical Oral Investigations · 18.05.2024 · 28 (6)

DOI: 10.1007/s00784-024-05655-w ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Oral Investigations, online erschienen am 18.05.2024. Verfasst von Madhura Rao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Karnataka…. Hauptthemen laut MEDLINE: Titanium, Orthodontic Brackets, Phosphorylcholine, Surface Properties. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Manipal Academy of Higher Education, Manipal.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

White spot lesions are the most common iatrogenic effect observed during orthodontic treatment. This study aimed to compare the surface characteristics and antibacterial action of uncoated and coated orthodontic brackets. Materials and methods Sixty commercially available stainless steel brackets were coated with TiO 2 nanotubes and methacryloyloxyethylphosphorylcholine. The sample was divided into Group 1: uncoated orthodontic brackets, Group 2: Stainless steel brackets with TiO 2 nanotubes coating, Group 3: Stainless steel brackets with methacryloyloxyethylphosphorylcholine coating, and Group 4: Stainless steel brackets with TiO 2 nanotubes combined with methacryloyloxyethylphosphorylcholine coating. Surface characterization was assessed using atomic force microscopy and scanning electron microscopy. Streptococcus mutans was selected to test the antibacterial ability of the orthodontic brackets, total bacterial adhesion and bacterial viability were assessed. The brackets were subjected to scanning electron microscopy to detect the presence of biofilm.

Results

The surface roughness was the greatest in Group 1 and least in Group 2 followed by Group 4 and Group 3 coated brackets. The optical density values were highest in Group 1 and lowest in Group 4. Comparison of colony counts revealed high counts in Group 1 and low counts in Group 4. A positive correlation between surface roughness and colony counts was obtained, however, was not statistically significant.

Conclusions

The coated orthodontic brackets exhibited less surface roughness than the uncoated orthodontic brackets. Group 4 coated orthodontic brackets showed the best antibacterial properties. Clinical relevance Coated orthodontic brackets prevent adhesion of streptococcus mutans and reduces plaque accumulation around the brackets thereby preventing formation of white spot lesions during orthodontic treatment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumOrthodontic BracketsPhosphorylcholineSurface PropertiesStreptococcus mutansAnti-Bacterial AgentsMicroscopy, Electron, ScanningNanotubesBacterial AdhesionMicroscopy, Atomic ForceMaterials TestingStainless SteelMethacrylatesBiofilmsCoated Materials, Biocompatible

Stichwörter der Autor:innen

MethacryloyloxyethylphosphorylcholineStainless steel orthodontic bracketsStreptococcus mutansTitanium dioxide nanotubeWhite spot lesions

Substanzen

TitaniumPhosphorylcholineAnti-Bacterial AgentsStainless SteelMethacrylatesCoated Materials, Biocompatibletitanium dioxide2-methacryloyloxyethyl phosphorylcholine

Autor:innen und Institutionen

  • Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
  • Department of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India. ashith.mv@manipal.edu.
  • Department Of Orthodontics and Dentofacial Orthopaedics, Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
  • Department of Microbiology, Kasturba Medical College Mangalore, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
  • Department Of Chemistry, National Institute of Technology, Surathkal, 575025, Karnataka, India.
  • Department Of Periodontics Manipal College of Dental Sciences Mangalore, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.

Förderung

  • Manipal Academy of Higher Education, Manipal

Zitieren

APA

Rao, M., Ashith, M. V., Suman, E., Isloor, A. M., Shetty, N. J., & Natarajan, S. (2024). Evaluation of the surface characteristics and antibacterial properties of Titanium dioxide nanotube and methacryloyloxyethylphosphorylcholine (MPC) coated orthodontic brackets-a comparative invitro study. Clinical Oral Investigations, 28(6). https://doi.org/10.1007/s00784-024-05655-w

Vancouver

Rao M, Ashith MV, Suman E, Isloor AM, Shetty NJ, Natarajan S. Evaluation of the surface characteristics and antibacterial properties of Titanium dioxide nanotube and methacryloyloxyethylphosphorylcholine (MPC) coated orthodontic brackets-a comparative invitro study. Clinical Oral Investigations. 2024;28(6). doi:10.1007/s00784-024-05655-w

BibTeX
@article{Rao2024,
  author = {Rao, Madhura and Ashith, M V and Suman, Ethel and Isloor, Arun M and Shetty, Neetha J and Natarajan, Srikant},
  title = {Evaluation of the surface characteristics and antibacterial properties of Titanium dioxide nanotube and methacryloyloxyethylphosphorylcholine (MPC) coated orthodontic brackets-a comparative invitro study},
  journal = {Clinical Oral Investigations},
  year = {2024},
  volume = {28},
  number = {6},
  doi = {10.1007/s00784-024-05655-w}
}
Kostenlos starten →