Determinants of Effective Height in Morphologically Normal Tricuspid Aortic Valves: A Computed Tomography-Based Anatomical Study
Interdisciplinary CardioVascular and Thoracic Surgery · 03.11.2026 · 41 (11)
DOI: 10.1093/icvts/ivag233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 20.08.2026. Verfasst von Keiichi Ishida und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan. Hauptthemen laut MEDLINE: Aortic Valve, Tricuspid Valve, Tomography, X-Ray Computed. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To analyse the relationship between effective height (eH) and other morphological parameters of the aortic valve complex when the aortic valve is closed.
Methods
We retrospectively analysed 105 patients (mean age 70.7 ± 10.1 years) with morphologically normal aortic valves, roots, or ascending aortas who had undergone electrocardiography-gated cardiac computed tomography as a screening test for the coronary artery, from August 2014 to December 2018. Parameters of the aortic valve complex configuration (eH, geometric height (gH), aortic annular diameter (AN diameter), sinus of Valsalva diameter, sinotubular junction (ST-J) diameter, commissure height, and Valsalva height) in diastole were measured using Ziostation2 software. Pearson’s correlation was used to evaluate the associations between the eH and other parameters. Multiple regression analysis was performed to evaluate the variables independently associated with eH.
Results
Significant associations were observed between the eH and gH, sinus of Valsalva diameter, ST-J diameter, commissure height, and Valsalva height (all P < .001) but not between eH and AN diameter (P = .227). Multivariable analysis showed that gH, AN diameter, and ST-J diameter were independently associated with eH (all P < .001; overall model fit: R2 = 0.739).
Conclusions
Our findings demonstrate that eH is strongly associated with gH, which remained independently associated after adjustment, along with aortic annular and ST-J diameters. These results provide quantitative in vivo evidence regarding the anatomical determinants of eH in morphologically normal tricuspid aortic valves and may serve as anatomical reference data for future research on individualized approaches to aortic valve repair.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Fukushima Medical University, 1 Hikarigaoka, Fukushima, 960-1295, Japan.
ORCID-Profile: Keiichi Ishida
Zitieren
APA
Ishida, K., Igarashi, T., Yokoyama, H., & Imasaka, K. (2026). Determinants of Effective Height in Morphologically Normal Tricuspid Aortic Valves: A Computed Tomography-Based Anatomical Study. Interdisciplinary CardioVascular and Thoracic Surgery, 41(11). https://doi.org/10.1093/icvts/ivag233
Vancouver
Ishida K, Igarashi T, Yokoyama H, Imasaka K. Determinants of Effective Height in Morphologically Normal Tricuspid Aortic Valves: A Computed Tomography-Based Anatomical Study. Interdisciplinary CardioVascular and Thoracic Surgery. 2026;41(11). doi:10.1093/icvts/ivag233
BibTeX
@article{Ishida2026,
author = {Ishida, Keiichi and Igarashi, Takashi and Yokoyama, Hitoshi and Imasaka, Kenichi},
title = {Determinants of Effective Height in Morphologically Normal Tricuspid Aortic Valves: A Computed Tomography-Based Anatomical Study},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
volume = {41},
number = {11},
doi = {10.1093/icvts/ivag233}
}
EUVIMED