EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

From 3D Printing to Clinical Application: A Patient-Specific Venous Model to Assess the Endovascular Implementation of Single-Lung Perfusion with Blood Flow Occlusion

Erik Claes iD, Stijn E Verleden, Annemiek Snoeckx, Gerdy Debeuckelaere iD, Joke De Raedemaecker, Thérèse S Lapperre, Jeroen M H Hendriks

Interdisciplinary CardioVascular and Thoracic Surgery · 2026

DOI: 10.1093/icvts/ivag025 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2026. Verfasst von Erik Claes und 6 weiteren Autor:innen. Beteiligte Einrichtung: ASTARC (Antwerp Surgical Training and Anatomy Research Centre), University of Antwerp, Wilrijk 2610, Belgium. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Pulmonary Artery, Endovascular Procedures, Lung Neoplasms. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Selective pulmonary artery perfusion with blood flow occlusion (SPAP-BFO), an experimental endovascular technique, has shown potential to enhance pulmonary drug delivery to the lung. Therefore, it becomes a potential minimally invasive technique for lung cancer and pulmonary metastases. Prior studies predominantly used animal models which do not adequately replicate human vascular anatomy, leaving the clinical feasibility of SPAP-BFO underexplored. To address this gap, we developed a patient-specific 3D model of the human venous system to evaluate the technical feasibility of SPAP-BFO.

Methods

A 1:1 scale 3D model of the human venous system was developed and printed based on CT scans of a patient. This model was connected to a perfusion system to simulate blood flow, enabling testing of the catheterization procedure under realistic clinical conditions. Two commercially available balloon catheters, Coda (Cook) and Reliant (Medtronic), were selected based on length and balloon diameter, and their feasibility of reaching and occluding the left and right pulmonary arteries were assessed.

Results

The model effectively simulated human anatomy and blood flow, allowing for both visual and fluoroscopic assessment of the procedure. Both Coda and Reliant catheters successfully reached the target location, when introduced via the femoral vein, and occluded the left and right pulmonary arteries without physically blocking contralateral flow or extending beyond the first bifurcation.

Conclusions

This patient-specific 3D model provided a valuable platform to evaluate the clinical feasibility of SPAP-BFO. The Coda and Reliant balloon catheters demonstrated effective occlusion of the pulmonary arteries, supporting their potential use in SPAP-BFO procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalPulmonary ArteryEndovascular ProceduresLung NeoplasmsPatient-Specific ModelingPulmonary CirculationBalloon OcclusionModels, CardiovascularHumansFeasibility Studies

Stichwörter der Autor:innen

3D modelblood flow occlusionendovascularlocoregionallung cancerselective pulmonary artery perfusion

Autor:innen und Institutionen

  • ASTARC (Antwerp Surgical Training and Anatomy Research Centre), University of Antwerp, Wilrijk 2610, Belgium.
  • Department of Thoracic and Vascular Surgery, University Hospital Antwerp, Edegem 2650, Belgium.
  • Department of Pulmonology, University Hospital Antwerp, Edegem 2650, Belgium.
  • Department of Radiology, University Hospital Antwerp, Edegem 2650, Belgium.
  • Perfusion Department, University Hospital Antwerp, Edegem 2650, Belgium.
  • LEMP (Laboratory of Experimental Medicine and Pediatrics), University of Antwerp, Wilrijk 2610, Belgium.

ORCID-Profile: Erik Claes, Gerdy Debeuckelaere

Zitieren

APA

Claes, E., Verleden, S. E., Snoeckx, A., Debeuckelaere, G., De Raedemaecker, J., Lapperre, T. S., & Hendriks, J. M. H. (2026). From 3D Printing to Clinical Application: A Patient-Specific Venous Model to Assess the Endovascular Implementation of Single-Lung Perfusion with Blood Flow Occlusion. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivag025

Vancouver

Claes E, Verleden SE, Snoeckx A, Debeuckelaere G, De Raedemaecker J, Lapperre TS, et al. From 3D Printing to Clinical Application: A Patient-Specific Venous Model to Assess the Endovascular Implementation of Single-Lung Perfusion with Blood Flow Occlusion. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivag025

BibTeX
@article{Claes2026,
  author = {Claes, Erik and Verleden, Stijn E and Snoeckx, Annemiek and Debeuckelaere, Gerdy and De Raedemaecker, Joke and Lapperre, Thérèse S and Hendriks, Jeroen M H},
  title = {From 3D Printing to Clinical Application: A Patient-Specific Venous Model to Assess the Endovascular Implementation of Single-Lung Perfusion with Blood Flow Occlusion},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2026},
  doi = {10.1093/icvts/ivag025}
}
Kostenlos starten →