An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis
Interdisciplinary CardioVascular and Thoracic Surgery · 2026
DOI: 10.1093/icvts/ivaf309 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2026. Verfasst von Mark Dirven und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Radboud University Medical Center, 6525 GA Nijmegen, Netherlands. Hauptthemen laut MEDLINE: Blood Vessel Prosthesis, Stents, Blood Vessel Prosthesis Implantation, Aorta, Thoracic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To report an initial experience with a novel off-the-shelf single branched thoracic aortic stent graft preserving various aortic arch vessels.
Methods
Our study is a retrospective cohort analysis of the largest European case series to date. We treated twenty patients for various aortic arch and descending pathology in the year 2024 and 2025.
Results
Twenty patients underwent successful implantation of the thoracic branched endoprosthesis (TBE) in the aortic arch and descending thoracic aorta. The sidebranch was applied to preserve the left subclavian artery in 17 patients, the innominate artery in two and the left carotid artery in one patient. Patients were treated for saccular arch aneurysms, chronic type B dissections with progressive dilatation, type 1a endoleaks after TEVAR, degenerative thoracic aneurysms, localized type A dissections or a first stage Crawford type II thoraco-abdominal aneurysm repair followed by a subsequent visceral branched endoprosthesis. The median follow-up period was six (1-12) months and technical results were satisfying. All TBE stentgrafts were implanted in the desired position with a patent branch on computed tomography angiography (CT-A) scan six weeks postoperatively. There was no in-hospital or 30-day mortality. Unfortunately, two patients suddenly died seven and eight weeks postoperatively of unknown causes. CT-A scan at six weeks showed no abnormalities concerning the aorta or TBE in both patients.
Conclusions
The present study demonstrates satisfying technical results with the GORE TBE which was successfully implanted for multiple indications of aortic arch or descending pathology. Longer follow-up and larger series are needed for verification.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, Radboud University Medical Center, 6525 GA Nijmegen, Netherlands.
- Department of Cardiothoracic Surgery, Radboud University Medical Center, 6525 GA Nijmegen, Netherlands.
- Department of Medical Imaging, Radboud University Medical Center, 6525 GA Nijmegen, Netherlands.
ORCID-Profile: Mark Dirven, Guillaume S C Geuzebroek, Robin H Heijmen
Zitieren
APA
Dirven, M., Geuzebroek, G. S. C., Nauta, F. J. H., van der Vijver, R. J., Knaapen, L., Geeraedts, T. E. A., Jenniskens, S. F. M., & Heijmen, R. H. (2026). An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf309
Vancouver
Dirven M, Geuzebroek GSC, Nauta FJH, van der Vijver RJ, Knaapen L, Geeraedts TEA, et al. An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivaf309
BibTeX
@article{Dirven2026,
author = {Dirven, Mark and Geuzebroek, Guillaume S C and Nauta, Foeke J H and van der Vijver, Rozemarijn J and Knaapen, Loes and Geeraedts, Tychon E A and Jenniskens, Sjoerd F M and Heijmen, Robin H},
title = {An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2026},
doi = {10.1093/icvts/ivaf309}
}
EUVIMED