Efficacy of intentional undersized thoracic endovascular repair for Stanford type B aortic dissection

Masaaki Naganuma, Yukihiro Hayatsu, Ryoichi Tsuruhara, Hayate Nomura, Naoya Terao, Kazuhiro Yamaya, Masaki Hata

Journal of Vascular Surgery · 2024

DOI: 10.1016/j.jvs.2024.04.043 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Vascular Surgery, 2024. Verfasst von Masaaki Naganuma und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Sendai Kosei Hospital, Sendai, Japan. Electronic address: naganuma0110@hotmail.co.jp. Hauptthemen laut MEDLINE: Aortic Dissection, Endovascular Procedures, Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Thoracic endovascular aneurysm repair (TEVAR) is widely used for the treatment of aortic dissection. Endograft oversizing is a risk factor for stent graft-induced new entry tears and retrograde type A aortic dissection. However, there is no clear consensus on the optimal graft size selection for Stanford type B acute or subacute aortic dissection (TBAD). Herein, we examined the safety and efficacy of TEVAR using an intentionally undersized endograft to treat TBAD. METHODS: This retrospective chart review study included 82 patients who underwent TEVAR for acute or subacute Stanford TBAD between 2015 and 2022. We measured the true lumen diameter just distal to the subclavian artery and opted for a stent graft of the same diameter. In instances where deformation resulting from false lumen pressure displacement was pronounced, we measured the diameter at the site just proximal to the subclavian artery. Patients' characteristics, procedural, in-hospital, and follow-up data, and aortic remodeling were analyzed. The aortic diameter was analyzed using one-way analysis of variance followed by Dunnett's test. Survival and freedom from reintervention were estimated using Kaplan-Meier curves. RESULTS: The follow-up rate was 98.4%. The mean age was 58.3 ± 12.3 years, and 76 were men (92.7%). The mean diameters of the stent graft and native proximal landing zone were 30.9 ± 3.2 mm and 30.8 ± 3.0 mm, respectively. The oversize rate of the stent graft in relation to the native proximal aortic diameter was 0.3% ± 4.7%. In-hospital mortality was observed in one patient, retrograde type A aortic dissection in one patient, distal stent graft-induced new entry tear in zero patients, and type 1a endoleak in 22 patients (26.8%). Type 1a endoleaks, characterized by antegrade false lumen blood flow originating from the primary entry, in 12 patients spontaneously disappeared within 1 year of follow-up. According to aortic remodeling, 59 patients (86.8%) achieved complete aortic remodeling at the aortic arch level and 51 (75.0%) at the eighth thoracic vertebral level. The diameters of the aortic arch and descending aorta were significantly reduced compared with the postoperative measurements (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic DissectionEndovascular ProceduresAortic Aneurysm, ThoracicBlood Vessel Prosthesis ImplantationBlood Vessel ProsthesisStentsProsthesis DesignHumansRetrospective StudiesMaleMiddle AgedFemaleAgedTime FactorsRisk FactorsTreatment OutcomePostoperative ComplicationsVascular RemodelingAdultEndovascular Aneurysm Repair

Stichwörter der Autor:innen

Aortic remodelingIntentional undersized TEVARType 1a endoleakType B aortic dissection

Autor:innen und Institutionen

  • Department of Cardiovascular Surgery, Sendai Kosei Hospital, Sendai, Japan. Electronic address: naganuma0110@hotmail.co.jp.
  • Department of Cardiovascular Surgery, Sendai Kosei Hospital, Sendai, Japan.

Zitieren

APA

Naganuma, M., Hayatsu, Y., Tsuruhara, R., Nomura, H., Terao, N., Yamaya, K., & Hata, M. (2024). Efficacy of intentional undersized thoracic endovascular repair for Stanford type B aortic dissection. Journal of Vascular Surgery. https://doi.org/10.1016/j.jvs.2024.04.043

Vancouver

Naganuma M, Hayatsu Y, Tsuruhara R, Nomura H, Terao N, Yamaya K, et al. Efficacy of intentional undersized thoracic endovascular repair for Stanford type B aortic dissection. Journal of Vascular Surgery. 2024. doi:10.1016/j.jvs.2024.04.043

BibTeX
@article{Naganuma2024,
  author = {Naganuma, Masaaki and Hayatsu, Yukihiro and Tsuruhara, Ryoichi and Nomura, Hayate and Terao, Naoya and Yamaya, Kazuhiro and Hata, Masaki},
  title = {Efficacy of intentional undersized thoracic endovascular repair for Stanford type B aortic dissection},
  journal = {Journal of Vascular Surgery},
  year = {2024},
  doi = {10.1016/j.jvs.2024.04.043}
}
Kostenlos starten →