Vergleichsstudie in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2026. Verfasst von Najla Sadat und 2 weiteren Autor:innen. Beteiligte Einrichtung: University Luebeck, Campus Luebeck, Luebeck, 23562, Germany. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Transcatheter Aortic Valve Replacement, Aortic Valve, Bioprosthesis. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Transcatheter aortic valve-in-valve is frequently performed in degenerated surgical valves. Notably, in small-sized surgical valves, bioprosthetic valve fracturing can improve the functional results of the transcatheter heart valve (THV). Therefore, this study aimed to investigate the impact of an expandable surgical valve on the functional improvement of 2 THV models.

Methods

An Inspiris Resilia (21 mm) and 2 different THV models—the self-expanding Evolut-PRO and the balloon-expandable SAPIEN 3 (each 23 and 26 mm)—were used for hydrodynamic testing at 4 different circulatory conditions in a pulse duplicator. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOA), minimal internal diameter (MID), and pin-wheeling index (PWI) of the THVs were analysed before and after expansion of the Inspiris Resilia with a non-compliant balloon (6 atm). Leaflet kinematics were evaluated by high-speed video recording. The internal and external diameters of Inspiris Resilia were measured with a calliper gauge. Fluoroscopic images were recorded.

Results

The Inspiris Resilia showed 2 mm enlarged internal and external stent diameters after expansion, which are fluoroscopically visible. EOA and MPG of the THVs as valve-in-valve did not change significantly after the expansion of the Inspiris Resilia. However, the Inspiris Resilia expansion improved leaflet kinematics, resulting in an increased GOA and a decreased PWI of the THVs as valve-in-valve.

Conclusions

The expansion of the Inspiris Resilia enlarged the stent diameter, resulting in improved leaflet kinematics of the THVs as valve-in-valve. These findings may be helpful for valve-in-valve interventions, especially in small-sized surgical valves.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisTranscatheter Aortic Valve ReplacementAortic ValveBioprosthesisProsthesis DesignHumansHydrodynamicsHemodynamicsBiomechanical PhenomenaMaterials Testing

Stichwörter der Autor:innen

Evolut-PROInspiris ResiliaSAPIEN 3TAVIbioprosthetic valve fracturetranscatheter heart valvevalve in valve

Autor:innen und Institutionen

  • University Luebeck, Campus Luebeck, Luebeck, 23562, Germany.
  • Department of Cardiac and Thoracic Vascular Surgery, University Heart Center Luebeck, University Medical Center Schleswig-Holstein, Luebeck, 23562, Germany.

ORCID-Profile: Najla Sadat, Michael Scharfschwerdt, Stephan Ensminger

Zitieren

APA

Sadat, N., Scharfschwerdt, M., & Ensminger, S. (2026). Functional Performance of 2 Different Transcatheter Heart Valve Models as Valve-in-Valve Before and After Expansion of the Inspiris Resilia: An In Vitro Study. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf305

Vancouver

Sadat N, Scharfschwerdt M, Ensminger S. Functional Performance of 2 Different Transcatheter Heart Valve Models as Valve-in-Valve Before and After Expansion of the Inspiris Resilia: An In Vitro Study. Interdisciplinary CardioVascular and Thoracic Surgery. 2026. doi:10.1093/icvts/ivaf305

BibTeX
@article{Sadat2026,
  author = {Sadat, Najla and Scharfschwerdt, Michael and Ensminger, Stephan},
  title = {Functional Performance of 2 Different Transcatheter Heart Valve Models as Valve-in-Valve Before and After Expansion of the Inspiris Resilia: An In Vitro Study},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2026},
  doi = {10.1093/icvts/ivaf305}
}
Kostenlos starten →