Cannula to Femoral Artery Diameter Ratio Predicts Potential Lower-Limb Ischemia in Minimally Invasive Cardiac Surgery With Femoral Cannulation
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2024
DOI: 10.1177/15569845241237212 ↗Kurz gefasst
Fachartikel in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2024. Verfasst von Takuya Nishijima und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Kyushu University Hospital, Fukuoka, Japan. Hauptthemen laut MEDLINE: Femoral Artery, Ischemia, Minimally Invasive Surgical Procedures, Lower Extremity. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.
Abstract (Originalsprache)
Objective
Lower-limb ischemia is a complication of minimally invasive cardiac surgery with femoral cannulation. Herein, we verified our strategy using distal perfusion cannulation (DPC) against this complication.
Methods
We retrospectively assessed 91 cases of aortic valve replacement with femoral cannulation between January 2019 and March 2023. DPC was applied when lower-limb tissue oxygenation index declined by ≥20%. The cannula to femoral artery diameter ratio (C/FA) was calculated by dividing the cannula size (Fr) divided by 3 by the femoral artery inner diameter (mm). Postoperative maximum creatinine kinase (CK max ), lactate dehydrogenase (LDH max ), and lactate levels were analyzed, and univariable logistic regression and receiver operating characteristic curve analyses were employed to determine DPC predictors and the cutoff C/FA for DPC, respectively. Patients without DPC were divided into 2 subgroups based on the cutoff C/FA for further comparisons.
Results
DPC was required in 9 patients. Symptomatic ischemia was not observed. All laboratory data were similar in the DPC and non-DPC groups. C/FA was significantly associated with DPC (odds ratio = 1.27, 95% confidence interval: 1.09 to 1.47, P = 0.002), and the cutoff C/FA was 0.70 (sensitivity = 0.89, specificity = 0.80). In the non-DPC group, CK max ( P = 0.027) and LDH max ( P = 0.041) were significantly higher in patients with C/FA ≥0.7 ( n = 16) than in those with C/FA
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Kyushu University Hospital, Fukuoka, Japan.
- Advanced Aortic Therapeutics, Faculty of Medicine, Kyushu University Graduate School of Medicine, Fukuoka, Japan.
ORCID-Profile: Takuya Nishijima, Tomoki Ushijima, Akira Shiose
Zitieren
APA
Nishijima, T., Ushijima, T., Fuke, Y., Kan-O, M., Kimura, S., Sonoda, H., & Shiose, A. (2024). Cannula to Femoral Artery Diameter Ratio Predicts Potential Lower-Limb Ischemia in Minimally Invasive Cardiac Surgery With Femoral Cannulation. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845241237212
Vancouver
Nishijima T, Ushijima T, Fuke Y, Kan-O M, Kimura S, Sonoda H, et al. Cannula to Femoral Artery Diameter Ratio Predicts Potential Lower-Limb Ischemia in Minimally Invasive Cardiac Surgery With Femoral Cannulation. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2024. doi:10.1177/15569845241237212
BibTeX
@article{Nishijima2024,
author = {Nishijima, Takuya and Ushijima, Tomoki and Fuke, Yoshifumi and Kan-O, Meikun and Kimura, Satoshi and Sonoda, Hiromichi and Shiose, Akira},
title = {Cannula to Femoral Artery Diameter Ratio Predicts Potential Lower-Limb Ischemia in Minimally Invasive Cardiac Surgery With Femoral Cannulation},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2024},
doi = {10.1177/15569845241237212}
}
EUVIMED