Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study
Interdisciplinary CardioVascular and Thoracic Surgery · 2025
DOI: 10.1093/icvts/ivaf086 ↗Kurz gefasst
Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Valentina Mescola und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Navarra University Hospital, Pamplona, Spain. Hauptthemen laut MEDLINE: Aortic Valve Insufficiency, Aortic Valve, Electrocardiography, Cardiac-Gated Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVES In young patients with type I/II aortic regurgitation, the feasibility of aortic valve (AV) repair has been traditionally evaluated with echocardiography. We evaluate electrocardiogram (ECG)-gated cardiac computed tomography as a complement to transoesophageal echocardiography in the preoperative assessment of aortic repairability. METHODS Patients undergoing non-urgent AV repair with or without aortic root replacement from October 2016 to May 2023 who had both imaging tests for the evaluation of AV repairability were included. The measurements obtained with echocardiography and ECG-gated scan of geometric height, aortic annulus and commissural orientation were compared using the intraclass correlation coefficient for inter-rater reliability. RESULTS All 24 patients were males, with a median age of 47.5 years (41.9–59.3). Of these, 87.5% presented severe aortic regurgitation; 62.5% had associated aortopathy. 58.3% were in New York Heart Association class I and the remnant 41.7% in class II. The AV was bicuspid in 62.5% of the patients. The intraclass correlation coefficient indicated excellent reliability of ECG-gated scan for commissural orientation (ICC = 0.98, 95% CI: 0.96–0.99) and conjoined cusp geometric height (ICC = 0.91, 95% CI: 0.74–0.97) in bicuspid AVs, while in tricuspid valves it showed good reliability for left cusp geometric height (ICC = 0.76, 95% CI: 0.19–0.93) and annular diameter (ICC = 0.8, 95% CI: 0.33–0.95). CONCLUSIONS ECG-gated cardiac scan complements echocardiography in aortic repair, showing excellent agreement for morphologic evaluation and commissural orientation. It is particularly reliable for geometric height in bicuspid valves and annular diameter and left cusp geometric height in tricuspid valves.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Navarra University Hospital, Pamplona, Spain.
- Department of Cardiovascular Surgery, Hospital Universitari Germans Trias i Pujol, Badalona, Spain.
- Department of Cardiology, Navarra University Hospital, Pamplona, Spain.
- IdiSNA, Navarra Institute for Healt Research, Pamplona, Spain.
ORCID-Profile: Valentina Mescola, Rafael Sádaba
Zitieren
APA
Mescola, V., Álvarez Asiaín, V., De Diego Candela, J., Navarro Echeverría, A., Gomez Blasco, F., Machado Fernandez, F., Jiménez Alfaro, L., & Sádaba, R. (2025). Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf086
Vancouver
Mescola V, Álvarez Asiaín V, De Diego Candela J, Navarro Echeverría A, Gomez Blasco F, Machado Fernandez F, et al. Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf086
BibTeX
@article{Mescola2025,
author = {Mescola, Valentina and Álvarez Asiaín, Virginia and De Diego Candela, Javier and Navarro Echeverría, Adela and Gomez Blasco, Félix and Machado Fernandez, Facundo and Jiménez Alfaro, Luis and Sádaba, Rafael},
title = {Use of complementary electrocardiogram-gated cardiac computed tomography in the assessment of aortic valve repairability: a pilot study},
journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
year = {2025},
doi = {10.1093/icvts/ivaf086}
}
EUVIMED