Fachartikel in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, online erschienen am 10.06.2025. Verfasst von Jordan L Green und 7 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK. Hauptthemen laut MEDLINE: Cardiopulmonary Bypass, Microplastics, Extracorporeal Circulation. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES This study determines the microplastic (MP) levels, dimension, shape, and chemical composition generated from conventional cardiopulmonary bypass and minimally invasive extracorporeal circulation (MiECC) circuits. METHODS In vitro conventional and MiECC circuits, mimicking realistic setups with 2 L of Hartmann’s solution were run for 90 min (n = 3 circuit runs each), filtered, and analysed using micro-Fourier transform infrared spectroscopy alongside procedural blanks (n = 5). RESULTS Conventional circuits produced 60.4 ± 7.6 MPs L−1h−1 (77.0% of the total particles). MiECC circuits produced 48.4 ± 31.3 MPs L−1h−1 (45.3% of total particles). MP levels in each circuit type were significantly elevated compared with procedural blank (n = 5) samples (5.6 ± 10.4 MPs L−1h−1) but did not differ with respect to the other. Twenty different MP polymer types were detected whereby polydimethyl siloxane, poly(decyl methacrylate), and poly(N-butyl methacrylate) represented the most MPs within conventional circuits. For MiECC, the most abundant were polypropylene, polyethylene, and polyamide. Average MP lengths differed significantly: 93.5 ± 98.6 µm (conventional) versus 62.0 ± 54.4 µm (MiECC) (P < 0.001), although widths did not differ. Film particles (48.2%) were the predominant shape for conventional circuits and fragments (50.5%) for MiECC. CONCLUSIONS Significant levels of MP particles were produced across the two systems. Future studies can determine the time points at which they are produced in machine use, to mitigate their production, as well as inform cell/tissue culture investigations into the clinical significance of their introduction into patients undergoing cardiac surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiopulmonary BypassMicroplasticsExtracorporeal CirculationSpectroscopy, Fourier Transform InfraredHumansParticle SizePolymersEquipment Design

Stichwörter der Autor:innen

FTIRcardiopulmonary bypassmicroplasticminimally invasive extracorporeal circulation (MiECC)polymer

Substanzen

MicroplasticsPolymers

Autor:innen und Institutionen

  • Centre for Cardiology and Cardiothoracic Surgery, Hull University Teaching Hospitals NHS Trust, Castle Hill Hospital, Hull, UK.
  • Hull York Medical School, University of Hull, Hull, UK.
  • School of Natural Sciences, University of Hull, Hull, UK.

ORCID-Profile: Jeanette M Rotchell, Mahmoud Loubani

Zitieren

APA

Green, J. L., Field, D. T., Bennett, R., Jenner, L. C., Chapman, E. C., Sadofsky, L. R., Rotchell, J. M., & Loubani, M. (2025). Microplastics in cardiopulmonary bypass: quantification and characterization of particles across systems. Interdisciplinary CardioVascular and Thoracic Surgery, 40(6). https://doi.org/10.1093/icvts/ivaf080

Vancouver

Green JL, Field DT, Bennett R, Jenner LC, Chapman EC, Sadofsky LR, et al. Microplastics in cardiopulmonary bypass: quantification and characterization of particles across systems. Interdisciplinary CardioVascular and Thoracic Surgery. 2025;40(6). doi:10.1093/icvts/ivaf080

BibTeX
@article{Green2025,
  author = {Green, Jordan L and Field, Daniel T and Bennett, Robert and Jenner, Lauren C and Chapman, Emma C and Sadofsky, Laura R and Rotchell, Jeanette M and Loubani, Mahmoud},
  title = {Microplastics in cardiopulmonary bypass: quantification and characterization of particles across systems},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2025},
  volume = {40},
  number = {6},
  doi = {10.1093/icvts/ivaf080}
}
Kostenlos starten →