EUVIMEDEUVIMED entdecken
Crossref

An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics

Hakan Eligul, Murat Kavruk, Ali Dogan Dursun, Dide Su Demirel, Omur Celikbicak, Gulay Bayramoglu, M Yakup Arica, Veli Cengiz Ozalp

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.119167 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Hakan Eligul und 7 weiteren Autor:innen. Beteiligte Einrichtung: Vocational School of Health Services, Atilim University, Ankara, 06830, Türkiye; Department of Biology, Graduate School of Science, Ankara University…. Hauptthemen laut MEDLINE: Biosensing Techniques, Flow Cytometry, Aptamers, Nucleotide, Microplastics. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Türkiye Bilimsel ve Teknolojik Araştırma Kurumu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nanoplastics are an emerging class of environmental contaminants whose analysis is limited by the difficulty of resolving both particle size and polymer identity at the submicrometre scale in a single high-throughput measurement. Here, a dual-parameter flow-cytometric biosensor was developed that combined polymer-selective DNA aptamers with violet side scatter (VSSC; 405 nm) to provide single-acquisition particle-size and polymer-identity readouts for nanoplastic targets. Polymer-specific aptamers against up to one-year sunlight equivalent photoaged polystyrene (PS), polyethylene terephthalate (PET), polyethylene (PE), polypropylene (PP), and polyvinyl chloride (PVC) nanoplastics were obtained by a Cell-SELEX procedure with counter-selection and were characterised by fluorescence saturation binding, giving apparent dissociation constants (KD) of 1.19-9.27 μg mL-1. Implemented on a CytoFLEX platform, the biosensor resolved polystyrene calibration beads down to ∼100 nm, below the practical cut-off of conventional 488 nm side scatter, and assigned polymer identity within the same VSSC window. A count-based calibration yielded limits of detection of 0.038-0.165 events μL-1 (≈40-200 particles mL-1), a polymer-independent figure of merit that was insensitive to fragment density or weathering state. Polymer-specific fluorescein (FITC)-channel-positive populations were retained in spiked ultrapure, tap, sea, and lake water matrices, with only modest matrix-dependent fluorescence attenuation that did not affect per-event polymer classification. The approach provided a potentially transferable biosensor architecture for nanoscale-particle analysis and was compatible with existing flow-cytometry data-analysis pipelines; adaptation to field-portable cytometers remains to be demonstrated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesFlow CytometryAptamers, NucleotideMicroplasticsPolymersParticle SizeLimit of DetectionPolystyrenesEquipment Design

Stichwörter der Autor:innen

Aptamer biosensorCell-SELEXDNA aptamersFlow cytometryNanoplasticsViolet side scatter

Substanzen

Aptamers, NucleotideMicroplasticsPolymersPolystyrenes

Autor:innen und Institutionen

  • Vocational School of Health Services, Atilim University, Ankara, 06830, Türkiye; Department of Biology, Graduate School of Science, Ankara University, Ankara, 06100, Türkiye.
  • Institute of Nanotechnology and Biotechnology, Istanbul University-Cerrahpaşa, Istanbul, 34500, Türkiye; Health Biotechnology Joint Research and Applications Center of Excellence, Istanbul, 34220, Türkiye.
  • Vocational School of Health Services, Atilim University, Ankara, 06830, Türkiye; Medicana International Hospital, Sögütozu, Ankara, 06520, Türkiye; Centre for Laboratory Animal Breeding and Experimental Research (ATUDEM…
  • Medicana International Hospital, Sögütozu, Ankara, 06520, Türkiye.
  • Department of Chemistry, Faculty of Sciences, Hacettepe University, Beytepe, Ankara, 06800, Türkiye.
  • Biochemical Process & Biomaterials Research Laboratory, Gazi University, Ankara, 06500, Türkiye; Department of Chemistry, Faculty of Sciences, Gazi University, Teknikokullar, Ankara, 06500, Türkiye.

Förderung

  • Türkiye Bilimsel ve Teknolojik Araştırma Kurumu

Zitieren

APA

Eligul, H., Kavruk, M., Dursun, A. D., Demirel, D. S., Celikbicak, O., Bayramoglu, G., Arica, M. Y., & Ozalp, V. C. (2026). An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.119167

Vancouver

Eligul H, Kavruk M, Dursun AD, Demirel DS, Celikbicak O, Bayramoglu G, et al. An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.119167

BibTeX
@article{Eligul2026,
  author = {Eligul, Hakan and Kavruk, Murat and Dursun, Ali Dogan and Demirel, Dide Su and Celikbicak, Omur and Bayramoglu, Gulay and Arica, M Yakup and Ozalp, Veli Cengiz},
  title = {An aptamer-guided flow-cytometric biosensor for simultaneous sizing and polymer identification of nanoplastics},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.119167}
}
Kostenlos starten →