EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing

Simon Mulier iD, Arno Fennema iD, Johan van Koll iD, Masih Mafi-Rad iD, Vidal Essebag iD, Atul Verma iD, Dominik Linz iD, Justin Luermans iD, Kevin Vernooy iD, Jacqueline Joza iD

Europace · 2026

DOI: 10.1093/europace/euag276 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Europace, 2026. Verfasst von Simon Mulier und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Cardiac Pacing, Artificial, Electrocardiography, Heart Atria, Atrial Fibrillation. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Bachmann bundle pacing (BBP) improves atrial synchrony by advancing LA activation, but quantifying inter-atrial synchronization remains challenging. This study evaluated whether lead V8 reflects posterolateral LA activation time and whether lead V8 can be used to assess the effect of BBP on LA activation. Methods and results Consecutive patients undergoing an electrophysiology study and ablation (Cohort 1) or BBP lead implantation (Cohort 2) were prospectively enrolled. Surface ECGs were recorded with the V5 electrode repositioned to the V8 location (2 cm below the inferior left scapula). LA activation was determined using the steepest negative downslope of the P-wave (NDAT-P-V8). Iso-V8 was defined as the time from P-wave onset to first positive deflection in lead V8. In Cohort 1, a coronary sinus (CS) catheter invasively determined activation timing at the posterolateral LA (mitral isthmus region). In Cohort 2, NDAT-P-V8 and iso-V8 were used to assess the effect of BBP on LA activation. In Cohort 1 (n = 50), NDAT-P-V8 strongly correlated with the latest CS activation (r = 0.94, P < 0.001). In Cohort 2 (n = 50), lead V8 facilitated intra-procedural assessment of LA activation. IAB was corrected in 20/23 (87%), accompanied by shortening of NDAT-P-V8 (from 120 ± 25 ms to 82 ± 17 ms, P < 0.001) and iso-V8 (from 51 ± 22 ms to 18 ± 17 ms, P < 0.001), consistent with earlier LA activation.

Conclusion

NDAT-P-V8 closely reflects the invasively determined timing of the posterolateral LA activation and provides a simple non-invasive marker to assess the effect of BBP on LA activation. Lead V8 may therefore help to assess and optimize atrial activation with BBP.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Pacing, ArtificialElectrocardiographyHeart AtriaAtrial FibrillationBundle of HisElectrophysiologic Techniques, CardiacHumansFemaleMaleAgedProspective StudiesMiddle AgedAction PotentialsTime FactorsCatheter AblationTreatment OutcomePredictive Value of Tests

Stichwörter der Autor:innen

Bachmann bundle pacingInteratrial synchronyLead V8Left atrial activationNegative derivative

Autor:innen und Institutionen

  • Department of Cardiology, Cardiovascular Research Institute Maastricht (CARIM), Maastricht, The Netherlands.
  • Department of Medicine, McGill University Health Center, Montréal, Québec, Canada.

ORCID-Profile: Simon Mulier, Arno Fennema, Johan van Koll, Masih Mafi-Rad, Vidal Essebag, Atul Verma, Dominik Linz, Justin Luermans, Kevin Vernooy, Jacqueline Joza

Zitieren

APA

Mulier, S., Fennema, A., van Koll, J., Mafi-Rad, M., Essebag, V., Verma, A., Linz, D., Luermans, J., Vernooy, K., & Joza, J. (2026). Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing. Europace. https://doi.org/10.1093/europace/euag276

Vancouver

Mulier S, Fennema A, van Koll J, Mafi-Rad M, Essebag V, Verma A, et al. Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing. Europace. 2026. doi:10.1093/europace/euag276

BibTeX
@article{Mulier2026,
  author = {Mulier, Simon and Fennema, Arno and van Koll, Johan and Mafi-Rad, Masih and Essebag, Vidal and Verma, Atul and Linz, Dominik and Luermans, Justin and Vernooy, Kevin and Joza, Jacqueline},
  title = {Non-invasive assessment of left atrial activation using lead V8 during Bachmann bundle pacing},
  journal = {Europace},
  year = {2026},
  doi = {10.1093/europace/euag276}
}
Kostenlos starten →