EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Removal of tine-based leadless pacemakers: insights from a large multicentre experience

Stjepan Jurisic iD, Jeanne du Fay de Lavallaz iD, Alessio Gasperetti iD, Mikhael El-Chami iD, Marco Schiavone iD, Ryan Cunnane, Wissam Mekary, Manuel Cerini iD, Harikrishna Tandri iD, Antonio Curnis, Martin Jurisic iD, Gianfranco Mitacchione iD und 10 weitere

Europace · 2026

DOI: 10.1093/europace/euag157 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Europace, 2026. Verfasst von Stjepan Jurisic und 21 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Zurich, Raemistrasse 100, Zurich CH-8091, Switzerland. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Device Removal. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

As implantation rates of leadless pacemakers (LPM) increase, a growing number of patients will require assessment of LPM removability. This multicentre study investigated the safety and feasibility of removal of tine-based LPMs. Methods and results We retrospectively analysed consecutive patients who underwent tine-based LPM removal between March 2016 and January 2024 across 11 centres in Europe and the USA. Demographic characteristics, indication for LPM removal, procedural success, and complication rates were assessed. A total of 85 patients [median age 73 years (IQR 64–82)] were included. Indications for LPM removal included temporary use after transvenous lead extraction (23.5%), upgrade to a biventricular pacing system (22.4%) or a transvenous dual-chamber pacemaker (9.4%), and increased pacing thresholds (21.2%). The median device dwell time was 96 days (IQR 29–320 days), and the overall procedural success rate was 96.5%. In the majority of cases, removal was performed using a steerable sheath in combination with a single-loop snare. Procedure-related adverse events occurred in 5.9% of patients, including two pericardial effusions and three cases of device embolization. Significant predictors of removal failure (n = 3, 3.5%) were apical device position [odds ratio (OR) 61.8.0; 95% confidence interval (CI) 2.5–788716.3, P = 0.008] and longer device dwell time [OR 1.4; 95% CI 1.1–2.4, P = 0.008].

Conclusion

Removal of tine-based LPMs, typically after short- to mid-term device dwell times, was generally feasible and safe.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialDevice RemovalHumansRetrospective StudiesFemaleDevice Lead ExtractionAgedMaleAged, 80 and overFeasibility StudiesEquipment DesignTreatment OutcomeEuropeUnited States

Stichwörter der Autor:innen

ExtractionLeadless pacemakerRetrieval/Removal

Autor:innen und Institutionen

  • Department of Cardiology, University Hospital Zurich, Raemistrasse 100, Zurich CH-8091, Switzerland.
  • Division of Cardiac Electrophysiology, University of Michigan Health Care, Ann Arbor, MI, USA.
  • Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy.
  • Arrhythmology and Electrophysiology Unit, San Raffaele Hospital, IRCCS, Milan, Italy.
  • Division of Cardiology, Section of Electrophysiology, Emory University School of Medicine, 550 W Peachtree St NE, Atlanta, GA 30308, USA.
  • Cardiology Department, Spedali Civili Hospital, University of Brescia, Brescia, Italy.

ORCID-Profile: Stjepan Jurisic, Jeanne du Fay de Lavallaz, Alessio Gasperetti, Mikhael El-Chami, Marco Schiavone, Manuel Cerini, Harikrishna Tandri, Martin Jurisic, Gianfranco Mitacchione, Claudio Tondo, Giovanni B Forleo, Shmaila Saleem-Talib, Hemanth Ramanna, Jean-Claude Deharo, Daniel Hofer, Alexander Breitenstein

Zitieren

APA

Jurisic, S., du Fay de Lavallaz, J., Gasperetti, A., El-Chami, M., Schiavone, M., Cunnane, R., Mekary, W., Cerini, M., Tandri, H., Curnis, A., Jurisic, M., Mitacchione, G., Tondo, C., Gulletta, S., Forleo, G. B., Rovaris, G., Saleh, K., Saleem-Talib, S., Ramanna, H., …, & Breitenstein, A. (2026). Removal of tine-based leadless pacemakers: insights from a large multicentre experience. Europace. https://doi.org/10.1093/europace/euag157

Vancouver

Jurisic S, du Fay de Lavallaz J, Gasperetti A, El-Chami M, Schiavone M, Cunnane R, et al. Removal of tine-based leadless pacemakers: insights from a large multicentre experience. Europace. 2026. doi:10.1093/europace/euag157

BibTeX
@article{Jurisic2026,
  author = {Jurisic, Stjepan and du Fay de Lavallaz, Jeanne and Gasperetti, Alessio and El-Chami, Mikhael and Schiavone, Marco and Cunnane, Ryan and Mekary, Wissam and Cerini, Manuel and Tandri, Harikrishna and Curnis, Antonio and Jurisic, Martin and Mitacchione, Gianfranco and Tondo, Claudio and Gulletta, Simone and Forleo, Giovanni B and Rovaris, Giovanni and Saleh, Karim and Saleem-Talib, Shmaila and Ramanna, Hemanth and Deharo, Jean-Claude and Hofer, Daniel and Breitenstein, Alexander},
  title = {Removal of tine-based leadless pacemakers: insights from a large multicentre experience},
  journal = {Europace},
  year = {2026},
  doi = {10.1093/europace/euag157}
}
Kostenlos starten →