Ganglionated plexi ablation impact on AF mechanisms and outcomes in patients with low scar burden
Europace · 2025
DOI: 10.1093/europace/euaf178 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2025. Verfasst von Shohreh Honarbakhsh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Queen Mary University of London, Mile End Road, London E1 4NS, UK. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Heart Atria. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation.
Abstract (Originalsprache)
Background and Aims Persistent atrial fibrillation (AF) ablation success rates remain limited. The aim was to evaluate the impact of ganglionated plexi (GP) ablation on AF mechanisms and outcomes in patients with low scar burden.
Methods
Patients undergoing persistent AF ablation were included. Patients that had <30% low voltage zones (LVZs) in the left atrium (LA) underwent pulmonary vein isolation (PVI) and GP ablation. Dominant frequency (DF), coronary sinus (CS) electrogram characteristics and AF inducibility score was assessed pre- and post-GP ablation. GP ablation response was determined.
Results
120 patients were included of which 84 (70.0%) patients had <30% LVZs and underwent GP ablation. An ablation response was seen in all patients (AF termination (66.7%) and CL slowing ≥30ms (33.3%)). The average DF, CS cycle length variability (CLV) and CS activation pattern stability (APS) pre-GP ablation was predictive of AF termination. GP ablation resulted in a significant change in the DF (6.3±1.2Hz pre-GP ablation vs. 5.1±1.0Hz; p<0.001), CS CLV (40.2±6.5ms vs. 28.2±6.8%; p<0.001) and CS APS (25.2±5.8% vs. 35.2±6.5%; p<0.001). AF inducibility was harder post-GP ablation than pre-GP ablation (3.8±1.2 AF inducibility score pre-ablation vs. 1.3±1.8 AF inducibility score post-ablation; p<0.001). Seventy-eight out of the 84 (92.9%) patients were free from AF/AT off anti-arrhythmic drugs at 12-months.
Conclusion
GP ablation results in a mechanistic impact in AF with an ablation response, changes in DF, CS electrogram characteristics and AF inducibility score. PVI and GP ablation in patients with minimal LVZs results in a high freedom from AF/AT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Queen Mary University of London, Mile End Road, London E1 4NS, UK.
- Barts Heart Centre, Barts Health NHS Trust, W Smithfield, London EC1A 7BE, UK.
ORCID-Profile: Shohreh Honarbakhsh, Caroline Roney, Sayed Al-Aidarous, Pier D Lambiase, Ross J Hunter
Förderung
- British Heart Foundation
Zitieren
APA
Honarbakhsh, S., Roney, C., Al-Aidarous, S., Horrach, C. V., Lambiase, P. D., & Hunter, R. J. (2025). Ganglionated plexi ablation impact on AF mechanisms and outcomes in patients with low scar burden. Europace. https://doi.org/10.1093/europace/euaf178
Vancouver
Honarbakhsh S, Roney C, Al-Aidarous S, Horrach CV, Lambiase PD, Hunter RJ. Ganglionated plexi ablation impact on AF mechanisms and outcomes in patients with low scar burden. Europace. 2025. doi:10.1093/europace/euaf178
BibTeX
@article{Honarbakhsh2025,
author = {Honarbakhsh, Shohreh and Roney, Caroline and Al-Aidarous, Sayed and Horrach, Caterina Vidal and Lambiase, Pier D and Hunter, Ross J},
title = {Ganglionated plexi ablation impact on AF mechanisms and outcomes in patients with low scar burden},
journal = {Europace},
year = {2025},
doi = {10.1093/europace/euaf178}
}
EUVIMED