Acute Efficacy of Pulsed‐Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings

Josef Hornof iD, Marek Hozman, Dalibor Heřman iD, Oleksii Romanenko, Sabri Hassouna, Jana Veselá, Věra Filipcová, Lukáš Povišer, Jakub Karch, Jana Hozmanová, Lucie Znojilová, Anna Molová und 2 weitere

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70236 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Josef Hornof und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Královské Vinohrady University Hospital, Prague, Czech Republic. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Mitral Valve, Cardiac Catheters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

There is limited data regarding the use of pulsed‐field ablation (PFA) for mitral isthmus (MI) ablation in patients with non‐paroxysmal atrial fibrillation (AF). Our aim was to assess the acute efficacy of MI ablation using a pentaspline PFA catheter with two different ablation settings.

Methods

Patients with AF undergoing ablation were consecutively enrolled. All patients underwent pulmonary vein isolation and left atrial posterior wall ablation. MI ablation was performed in up to 4 series (9 PFA applications each) in Cohort A, or in up to 3 series (20 PFA applications each) in Cohort B. Each series was followed by a 20‐min observation period to verify the durability of the MI block. The primary endpoints were a first‐pass MI block and a final MI block after all ablation series.

Results

Between September 2024 and June 2025, 70 patients were enrolled: 30 in Cohort A and 40 in Cohort B. A first‐pass MI block was achieved in 10 (33.3%) patients in Cohort A and 28 (70%) patients in Cohort B ( p = 0.003). A final MI block was present in 27 (90%) and 35 (87.5%) patients in Cohort A and B, respectively ( p = 1.00). The median reconduction time was 6 min (IQR 2.8–9.4) in Cohort A and 5 min (IQR 2.6–8.7) in Cohort B. No major complications occurred.

Conclusion

Using series of 20 PFA applications increased the success rate of a first‐pass MI block to 70%. An observation period is recommended to verify the durability of MI block in PFA. Clinical Trial Registration: NCT06803238.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationMitral ValveCardiac CathetersPulmonary VeinsHumansMaleFemaleMiddle AgedTreatment OutcomeAgedAction PotentialsTime FactorsHeart RateEquipment Design

Stichwörter der Autor:innen

atrial fibrillationmitral isthmus ablationpentaspline catheterpulsed‐field ablationreconduction

Autor:innen und Institutionen

  • Department of Cardiology, Královské Vinohrady University Hospital, Prague, Czech Republic.
  • Third Faculty of Medicine, Charles University, Prague, Czech Republic.
  • Cardiocenter, Karlovy Vary Hospital, Karlovy Vary, Czech Republic.

ORCID-Profile: Josef Hornof, Dalibor Heřman

Zitieren

APA

Hornof, J., Hozman, M., Heřman, D., Romanenko, O., Hassouna, S., Veselá, J., Filipcová, V., Povišer, L., Karch, J., Hozmanová, J., Znojilová, L., Molová, A., Pěnkava, V., & Osmančík, P. (2026). Acute Efficacy of Pulsed‐Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70236

Vancouver

Hornof J, Hozman M, Heřman D, Romanenko O, Hassouna S, Veselá J, et al. Acute Efficacy of Pulsed‐Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70236

BibTeX
@article{Hornof2026,
  author = {Hornof, Josef and Hozman, Marek and Heřman, Dalibor and Romanenko, Oleksii and Hassouna, Sabri and Veselá, Jana and Filipcová, Věra and Povišer, Lukáš and Karch, Jakub and Hozmanová, Jana and Znojilová, Lucie and Molová, Anna and Pěnkava, Vojtěch and Osmančík, Pavel},
  title = {Acute Efficacy of Pulsed‐Field Ablation of the Mitral Isthmus Using a Pentaspline Catheter and Two Different Ablation Settings},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70236}
}
Kostenlos starten →