Safety and feasibility of pulsed field ablation with a pentaspline catheter in patients with cardiac implantable electronic devices: a multicentre experience
Europace · 04.08.2025 · 27 (8)
DOI: 10.1093/europace/euaf132 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, online erschienen am 26.06.2025. Verfasst von Saverio Iacopino und 15 weiteren Autor:innen. Beteiligte Einrichtung: Maria Cecilia Hospital, GVM Care & Research, Cotignola, Italy. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Saverio Iacopino, MD, Claudio Tondo, MD, PhD, Stefano Bianchi, MD, Antonio Dello Russo, MD, PhD, Ruggero Maggio, MD, Giovanni Rovaris, MD, Matteo Bertini,
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Maria Cecilia Hospital, GVM Care & Research, Cotignola, Italy.
- Department of Clinical Electrophysiology & Cardiac Pacing, Monzino Cardiological Center, IRCCS, Milan, Italy.
- Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
- Center of Excellence in Cardiovascular Sciences, Ospedale Isola Tiberina-Gemelli Isola, Rome, Italy.
- Cardiology and Arrhythmology Clinic, Marche University Hospital, Ancona, Italy.
- Department of Biomedical Sciences and Public Health, Marche Polytechnic University, Ancona, Italy.
ORCID-Profile: Saverio Iacopino, Claudio Tondo, Stefano Bianchi, Antonio Dello Russo, Ruggero Maggio, Matteo Bertini, Marco Galeazzi, Francesco Solimene, Stefano Bandino, Mario Volpicelli, Andrea Di Cori, Maurizio Malacrida, Sakis Themistoclakis
Zitieren
APA
Iacopino, S., Tondo, C., Bianchi, S., Dello Russo, A., Maggio, R., Rovaris, G., Bertini, M., Galeazzi, M., Rossillo, A., Zingarini, G., Solimene, F., Bandino, S., Volpicelli, M., Di Cori, A., Malacrida, M., & Themistoclakis, S. (2025). Safety and feasibility of pulsed field ablation with a pentaspline catheter in patients with cardiac implantable electronic devices: a multicentre experience. Europace, 27(8). https://doi.org/10.1093/europace/euaf132
Vancouver
Iacopino S, Tondo C, Bianchi S, Dello Russo A, Maggio R, Rovaris G, et al. Safety and feasibility of pulsed field ablation with a pentaspline catheter in patients with cardiac implantable electronic devices: a multicentre experience. Europace. 2025;27(8). doi:10.1093/europace/euaf132
BibTeX
@article{Iacopino2025,
author = {Iacopino, Saverio and Tondo, Claudio and Bianchi, Stefano and Dello Russo, Antonio and Maggio, Ruggero and Rovaris, Giovanni and Bertini, Matteo and Galeazzi, Marco and Rossillo, Antonio and Zingarini, Gianluca and Solimene, Francesco and Bandino, Stefano and Volpicelli, Mario and Di Cori, Andrea and Malacrida, Maurizio and Themistoclakis, Sakis},
title = {Safety and feasibility of pulsed field ablation with a pentaspline catheter in patients with cardiac implantable electronic devices: a multicentre experience},
journal = {Europace},
year = {2025},
volume = {27},
number = {8},
doi = {10.1093/europace/euaf132}
}