Adverse events during catheter ablation in patients with cardiac implantable electronic devices
Heart Rhythm · 2026-05 · 23 (5) · e723-e732
DOI: 10.1016/j.hrthm.2026.02.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2026-05. Verfasst von Shiloh Sison und 2 weiteren Autor:innen. Beteiligte Einrichtung: Cardiac Rhythm Management, Abbott Laboratories, Sunnyvale, California. Hauptthemen laut MEDLINE: Catheter Ablation, Defibrillators, Implantable, Pacemaker, Artificial, Postoperative Complications. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Cardiovascular Research Foundation.
Themen: Patientensicherheit
Abstract (Originalsprache)
BACKGROUND: Reviews of adverse events (AEs) in patients with cardiac implantable electronic devices (CIEDs) during catheter ablation predate newer devices, procedures, and ablation technologies (eg, pulsed field [PF], lattice-tip radiofrequency [RF]). OBJECTIVE: This study aimed to characterize AEs in contemporary patients with CIED undergoing ablation and identify implications for safer practice. METHODS: We analyzed 433 AEs from the US Food and Drug Administration's Manufacturer and User Facility Device Experience database and peer-reviewed literature (2020-2025), focusing on newer technologies. RESULTS: Ablation catheters or energy caused 97% of AEs (RF 89%; PF 8%). Mechanical interactions caused 32% of AEs (30% dislodgements). Electromagnetic interactions (68%) included myocardial thermal injury (34%), generator dysfunction (20%), oversensing (9%), and induction of ventricular fibrillation (5%). Interventions (generator/lead replacement/repositioning) occurred in 56% of cases. Thermal injury with loss of capture necessitated replacement or repositioning of 53 transvenous leads and 32 leadless pacemakers, often when ablation sites were ≥2 cm from tip electrodes. Lattice-tip RF near Biotronik implantable cardioverter-defibrillator leads induced 14 of 15 RF-related ventricular fibrillations. PF accounted for all 6 confirmed generator failures. No cryoablation AEs were reported. CONCLUSION: This first and largest comprehensive series of ablation-related complications in contemporary patients with CIED underscores the underappreciated risks of older technology and highlights novel risks of evolving technologies. A notable finding is that most threshold elevations requiring intervention occurred at ablation sites remote from CIED tip electrodes. More than 40% of AEs seemed largely preventable, suggesting gaps in procedural workflows. Our results suggest opportunities to improve clinical practices and CIED design to safeguard patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiac Rhythm Management, Abbott Laboratories, Sunnyvale, California.
- Division of Cardiology, Virginia Commonwealth University School of Medicine, Richmond, Virginia.
- Smidt Heart Center at Cedars Sinai Medical Center, Los Angeles, California. Electronic address: charles.swerdlow@cshs.org.
Förderung
- Cardiovascular Research Foundation
Zitieren
APA
Sison, S., Ellenbogen, K. A., & Swerdlow, C. D. (2026). Adverse events during catheter ablation in patients with cardiac implantable electronic devices. Heart Rhythm, 23(5), e723-e732. https://doi.org/10.1016/j.hrthm.2026.02.008
Vancouver
Sison S, Ellenbogen KA, Swerdlow CD. Adverse events during catheter ablation in patients with cardiac implantable electronic devices. Heart Rhythm. 2026;23(5):e723-e732. doi:10.1016/j.hrthm.2026.02.008
BibTeX
@article{Sison2026,
author = {Sison, Shiloh and Ellenbogen, Kenneth A and Swerdlow, Charles D},
title = {Adverse events during catheter ablation in patients with cardiac implantable electronic devices},
journal = {Heart Rhythm},
year = {2026},
volume = {23},
number = {5},
pages = {e723--e732},
doi = {10.1016/j.hrthm.2026.02.008}
}
EUVIMED