EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Safety and Efficacy of Right‐ Versus Left‐Sided Transvenous Lead Extraction

Nadine Molitor iD, Caroline Wiederkehr, Jan Steffel, Andreas Häberlin, Alexander Breitenstein iD, Daniel Hofer iD

Journal of Cardiovascular Electrophysiology · 2026

DOI: 10.1111/jce.70497 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2026. Verfasst von Nadine Molitor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland. Hauptthemen laut MEDLINE: Device Lead Extraction, Device Removal, Pacemaker, Artificial, Defibrillators, Implantable. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aims Transvenous lead extraction (TLE) is increasingly performed for malfunction or infection of cardiac implantable electronic devices. Because of anatomic differences, TLE for right‐sided (RS) electrodes may differ in outcome. This study aimed to evaluate whether RS TLE differs in patient characteristics and outcomes compared to left‐sided TLE.

Methods

We retrospectively analyzed patients who underwent TLE at the University Hospital Zurich from 2013 until 2023 regarding clinical and radiological success and complications.

Results

A total of 556 patients underwent 568 TLE from January 2013 until December 2023. Patients with RS TLE procedures ( n = 147, 25.9%) were older, more often PM‐dependent, had longer lead dwell time, more leads with passive fixation and were more often extracted for infection. RS TLE procedures had a longer procedure duration (130 vs. 108 min, p = 0.002), more often needed a snare‐bailout strategy (22% vs. 10%, p = 0.0.45), resulted in lower radiological success rates (88.4% vs. 93.8%, p = 0.045) and more major as well as minor complication rates.

Conclusion

In our retrospective single‐center analysis, RS TLE Procedures were more challenging concerning patient characteristics and resulted in lower TLE success as well as higher complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Device Lead ExtractionDevice RemovalPacemaker, ArtificialDefibrillators, ImplantableProsthesis-Related InfectionsHumansRetrospective StudiesTreatment OutcomeFemaleMaleTime FactorsRisk FactorsAgedMiddle AgedRisk AssessmentSwitzerlandAged, 80 and over

Stichwörter der Autor:innen

complicationlead extractionrightright‐sidedsuccess

Autor:innen und Institutionen

  • Division of Electrophysiology, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
  • Department of Cardiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
  • ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.

ORCID-Profile: Nadine Molitor, Alexander Breitenstein, Daniel Hofer

Zitieren

APA

Molitor, N., Wiederkehr, C., Steffel, J., Häberlin, A., Breitenstein, A., & Hofer, D. (2026). Safety and Efficacy of Right‐ Versus Left‐Sided Transvenous Lead Extraction. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70497

Vancouver

Molitor N, Wiederkehr C, Steffel J, Häberlin A, Breitenstein A, Hofer D. Safety and Efficacy of Right‐ Versus Left‐Sided Transvenous Lead Extraction. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70497

BibTeX
@article{Molitor2026,
  author = {Molitor, Nadine and Wiederkehr, Caroline and Steffel, Jan and Häberlin, Andreas and Breitenstein, Alexander and Hofer, Daniel},
  title = {Safety and Efficacy of Right‐ Versus Left‐Sided Transvenous Lead Extraction},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70497}
}
Kostenlos starten →