Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping
Europace · 2024
DOI: 10.1093/europace/euae067 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2024. Verfasst von Thomas Fink und 12 weiteren Autor:innen. Beteiligte Einrichtung: Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Georgstraße 11, 32545 Bad Oeynhausen, Germany. Hauptthemen laut MEDLINE: Atrial Fibrillation, Atrial Appendage, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Aims
Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. Methods and results Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96).
Conclusion
The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Georgstraße 11, 32545 Bad Oeynhausen, Germany.
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.
ORCID-Profile: Thomas Fink, Flemming Nischik, Leonard Bergau, Denise Guckel, Mustapha El Hamriti, Martin Braun, Stephan Winnik, Maxim Didenko, Guram Imnadze, Philipp Sommer, Christian Sohns
Zitieren
APA
Fink, T., Sciacca, V., Nischik, F., Bergau, L., Guckel, D., El Hamriti, M., Khalaph, M., Braun, M., Winnik, S., Didenko, M., Imnadze, G., Sommer, P., & Sohns, C. (2024). Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping. Europace. https://doi.org/10.1093/europace/euae067
Vancouver
Fink T, Sciacca V, Nischik F, Bergau L, Guckel D, El Hamriti M, et al. Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping. Europace. 2024. doi:10.1093/europace/euae067
BibTeX
@article{Fink2024,
author = {Fink, Thomas and Sciacca, Vanessa and Nischik, Flemming and Bergau, Leonard and Guckel, Denise and El Hamriti, Mustapha and Khalaph, Moneeb and Braun, Martin and Winnik, Stephan and Didenko, Maxim and Imnadze, Guram and Sommer, Philipp and Sohns, Christian},
title = {Atrial fibrillation ablation workflow optimization facilitated by high-power short-duration ablation and high-resolution mapping},
journal = {Europace},
year = {2024},
doi = {10.1093/europace/euae067}
}
EUVIMED