Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia
Europace · 2023
DOI: 10.1093/europace/euad341 ↗Kurz gefasst
Fachartikel in der Zeitschrift Europace, 2023. Verfasst von Vera Loen und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physiology, University Medical Center Utrecht, Yalelaan 50, 3584 CM Utrecht, The Netherlands. Hauptthemen laut MEDLINE: Myocardial Ischemia, Coronary Artery Disease. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Research Council, framework of PREDICT II, Dutch Cardiovascular Alliance.
Abstract (Originalsprache)
Aims
An automated method for determination of short-term variability (STV) of repolarization on intracardiac electrograms (STV-ARIauto) has previously been developed for arrhythmic risk monitoring by cardiac implantable devices, and has proved effective in predicting ventricular arrhythmias (VA) and guiding preventive high-rate pacing (HRP) in a canine model. Current study aimed to assess (i) STV-ARIauto in relation to VA occurrence and secondarily (ii-a) to confirm the predictive capacity of STV from the QT interval and (ii-b) explore the effect of HRP on arrhythmic outcomes in a porcine model of acute myocardial infarction (MI). Methods and results Myocardial infarction was induced in 15 pigs. In 7/15 pigs, STV-QT was assessed at baseline, occlusion, 1 min before VA, and just before VA. Eight of the 15 pigs were additionally monitored with an electrogram catheter in the right ventricle, underwent echocardiography at baseline and reperfusion, and were randomized to paced or control group. Paced group received atrial pacing at 20 beats per min faster than sinus rhythm 1 min after occlusion. Short-term variability increased prior to VA in both STV modalities. The percentage change in STV from baseline to successive timepoints correlated well between STV-QT and STV-ARIauto. High-rate pacing did not improve arrhythmic outcomes and was accompanied by a stronger decrease in ejection fraction.
Conclusion
STV-ARIauto values increase before VA onset, alike STV-QT in a porcine model of MI, indicating imminent arrhythmias. This highlights the potential of automatic monitoring of arrhythmic risk by cardiac devices through STV-ARIauto and subsequently initiates preventive strategies. Continuous HRP during onset of acute MI did not improve arrhythmic outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physiology, University Medical Center Utrecht, Yalelaan 50, 3584 CM Utrecht, The Netherlands.
- Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands.
- Cardiac Rhythm Management, Medtronic Inc., Mounds View, MN, USA.
- CRM EMEA Medical Science, Medtronic Bakken Research Center, Maastricht, The Netherlands.
- Experimental Cardiology Laboratory, Department of Cardiology, University Medical Center Utrecht, Utrecht, The Netherlands.
- Department of Medical Biology, Amsterdam Cardiovascular Sciences, Amsterdam University Medical Center, Amsterdam, The Netherlands.
ORCID-Profile: Vera Loen, Agnieszka Smoczynska, Aina Cervera-Barea, Gerard J J Boink, Joost P G Sluijter, Marcel A G van der Heyden, Mathias Meine, Marc A Vos
Förderung
- European Research Council
- framework of PREDICT II
- Dutch Cardiovascular Alliance
- Public Private Partnership
- Dutch Heart Foundation
- Health Holland LentiPace II
- Horizon 2020
- Eurostars
Zitieren
APA
Loen, V., Smoczynska, A., Aranda Hernandez, A., Scheerder, C. O. S., van der Linde, B. H. R., Beekman, H. D. M., Cervera-Barea, A., Boink, G. J. J., Sluijter, J. P. G., van der Heyden, M. A. G., Meine, M., & Vos, M. A. (2023). Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia. Europace. https://doi.org/10.1093/europace/euad341
Vancouver
Loen V, Smoczynska A, Aranda Hernandez A, Scheerder COS, van der Linde BHR, Beekman HDM, et al. Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia. Europace. 2023. doi:10.1093/europace/euad341
BibTeX
@article{Loen2023,
author = {Loen, Vera and Smoczynska, Agnieszka and Aranda Hernandez, Alfonso and Scheerder, Coert O S and van der Linde, Britt H R and Beekman, Henriëtte D M and Cervera-Barea, Aina and Boink, Gerard J J and Sluijter, Joost P G and van der Heyden, Marcel A G and Meine, Mathias and Vos, Marc A},
title = {Automatic measurement of short-term variability of repolarization to indicate ventricular arrhythmias in a porcine model of cardiac ischaemia},
journal = {Europace},
year = {2023},
doi = {10.1093/europace/euad341}
}
EUVIMED