Wireless Single-Lead versus Standard 12-Lead ECG, for ST-Segment Deviation during Adenosine Cardiac Stress Scintigraphy
Sensors · 2023
DOI: 10.3390/s23062962 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2023. Verfasst von Luna Fabricius Ekenberg und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Centre for Cancer and Organ Diseases, Rigshospitalet Copenhagen University Hospital, Blegdamsvej 9, 2200 Copenhagen, De…. Hauptthemen laut MEDLINE: Myocardial Ischemia, Coronary Artery Disease. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Innovation Fund Denmark, Novo Nordic Foundation, Danish Cancer Society.
Abstract (Originalsprache)
Wearable wireless electrocardiographic (ECG) monitoring is well-proven for arrythmia detection, but ischemia detection accuracy is not well-described. We aimed to assess the agreement of ST-segment deviation from single- versus 12-lead ECG and their accuracy for the detection of reversible ischemia. Bias and limits of agreement (LoA) were calculated between maximum deviations in ST segments from single- and 12-lead ECG during 82Rb PET-myocardial cardiac stress scintigraphy. Sensitivity and specificity for reversible anterior-lateral myocardial ischemia detection were assessed for both ECG methods, using perfusion imaging results as a reference. Out of 110 patients included, 93 were analyzed. The maximum difference between single- and 12-lead ECG was seen in II (−0.019 mV). The widest LoA was seen in V5, with an upper LoA of 0.145 mV (0.118 to 0.172) and a lower LoA of −0.155 mV (−0.182 to −0.128). Ischemia was seen in 24 patients. Single-lead and 12-lead ECG both had poor accuracy for the detection of reversible anterolateral ischemia during the test: single-lead ECG had a sensitivity of 8.3% (1.0–27.0%) and specificity of 89.9% (80.2–95.8%), and 12-lead ECG a sensitivity of 12.5% (3.0–34.4%) and a specificity of 91.3% (82.0–96.7%). In conclusion, agreement was within predefined acceptable criteria for ST deviations, and both methods had high specificity but poor sensitivity for the detection of anterolateral reversible ischemia. Additional studies must confirm these results and their clinical relevance, especially in the light of the poor sensitivity for detecting reversible anterolateral cardiac ischemia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Centre for Cancer and Organ Diseases, Rigshospitalet Copenhagen University Hospital, Blegdamsvej 9, 2200 Copenhagen, Denmark.
- Department of Cardiology, Rigshospitalet Copenhagen University Hospital, 2100 Copenhagen, Denmark.
- Biomedical Signal Processing & AI Research Group, Digital Health Section, Department of Health Technology, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark.
- Department of Clinical Physiological and Nuclear Medicine, Center for Diagnostics, Rigshospitalet Copenhagen University Hospital, 2100 Copenhagen, Denmark.
- Department of Anaesthesia and Intensive Care, Copenhagen University Hospital-Bispebjerg and Frederiksberg Hospital, 2400 Copenhagen, Denmark.
- Department of Clinical Medicine, University of Copenhagen, 2200 Copenhagen, Denmark.
ORCID-Profile: Søren M Rasmussen, Jesper Mølgaard, Christian S Meyhoff, Eske K Aasvang
Förderung
- Innovation Fund Denmark
- Novo Nordic Foundation
- Danish Cancer Society
- Steno Diabetes Center Denmark
- Copenhagen Center for Health Technology
- Radiometer, A.P. Møller Foundation
Zitieren
APA
Fabricius Ekenberg, L., Høfsten, D. E., Rasmussen, S. M., Mølgaard, J., Hasbak, P., Sørensen, H. B. D., Meyhoff, C. S., & Aasvang, E. K. (2023). Wireless Single-Lead versus Standard 12-Lead ECG, for ST-Segment Deviation during Adenosine Cardiac Stress Scintigraphy. Sensors. https://doi.org/10.3390/s23062962
Vancouver
Fabricius Ekenberg L, Høfsten DE, Rasmussen SM, Mølgaard J, Hasbak P, Sørensen HBD, et al. Wireless Single-Lead versus Standard 12-Lead ECG, for ST-Segment Deviation during Adenosine Cardiac Stress Scintigraphy. Sensors. 2023. doi:10.3390/s23062962
BibTeX
@article{FabriciusEkenberg2023,
author = {Fabricius Ekenberg, Luna and Høfsten, Dan Eik and Rasmussen, Søren M and Mølgaard, Jesper and Hasbak, Philip and Sørensen, Helge B D and Meyhoff, Christian S and Aasvang, Eske K},
title = {Wireless Single-Lead versus Standard 12-Lead ECG, for ST-Segment Deviation during Adenosine Cardiac Stress Scintigraphy},
journal = {Sensors},
year = {2023},
doi = {10.3390/s23062962}
}
EUVIMED