EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation

Julian Müller iD, Karin Nentwich iD, Artur Berkovitz iD, Elena Ene iD, Kai Sonne iD, Vitaly Zhuravlev, Ivaylo Chakarov iD, Sebastian Barth iD, Christian Waechter iD, Michael Behnes iD, Philipp Halbfass iD, Thomas Deneke iD

EP Europace · 2023

DOI: 10.1093/europace/euad053 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EP Europace, 2023. Verfasst von Julian Müller und 11 weiteren Autor:innen. Beteiligte Einrichtung: Clinic for Interventional Electrophysiology, Heart Centre Bad Neustadt, Von-Guttenberg-Straße 11, 97616 Bad Neustadt a. d. Saale, Germany. Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. Methods and results Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index–guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator’s preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427–16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets.

Conclusion

High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCatheter AblationPulmonary VeinsHumansMaleFemaleFollow-Up StudiesTreatment OutcomeEsophagusArtificial IntelligenceRecurrence

Stichwörter der Autor:innen

Ablation indexAtrial fibrillationEndoscopically detected oesophageal lesionsHigh-power short-duration ablationPrognosis bullPulmonary vein isolation

Autor:innen und Institutionen

  • Clinic for Interventional Electrophysiology, Heart Centre Bad Neustadt, Von-Guttenberg-Straße 11, 97616 Bad Neustadt a. d. Saale, Germany.
  • Department of Cardiology and Angiology, Philipps-University Marburg, Baldingerstraße, 35034 Marburg, Germany.
  • First Department of Medicine, University Medical Centre Mannheim (UMM), Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany.
  • Department of Cardiology, Oldenburg, Rahel-Straus-Straße 10, 26133 OldenburgGermany.

ORCID-Profile: Julian Müller, Karin Nentwich, Artur Berkovitz, Elena Ene, Kai Sonne, Ivaylo Chakarov, Sebastian Barth, Christian Waechter, Michael Behnes, Philipp Halbfass, Thomas Deneke

Zitieren

APA

Müller, J., Nentwich, K., Berkovitz, A., Ene, E., Sonne, K., Zhuravlev, V., Chakarov, I., Barth, S., Waechter, C., Behnes, M., Halbfass, P., & Deneke, T. (2023). Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation. EP Europace. https://doi.org/10.1093/europace/euad053

Vancouver

Müller J, Nentwich K, Berkovitz A, Ene E, Sonne K, Zhuravlev V, et al. Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation. EP Europace. 2023. doi:10.1093/europace/euad053

BibTeX
@article{Mller2023,
  author = {Müller, Julian and Nentwich, Karin and Berkovitz, Artur and Ene, Elena and Sonne, Kai and Zhuravlev, Vitaly and Chakarov, Ivaylo and Barth, Sebastian and Waechter, Christian and Behnes, Michael and Halbfass, Philipp and Deneke, Thomas},
  title = {Acute oesophageal safety and long-term follow-up of AI-guided high-power short-duration with 50 W for atrial fibrillation ablation},
  journal = {EP Europace},
  year = {2023},
  doi = {10.1093/europace/euad053}
}
Kostenlos starten →