EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Agreement of thermodilution and direct Fick methods for cardiac output across varying haemodynamic conditions

Michael Melin, Ida Haugen Löfman, Dmitri Matan, Magnus Nygren, Bahira Shahim, Lars H Lund, Aristomenis Manouras iD

ESC Heart Failure · 2026

DOI: 10.1093/eschf/xvaf001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ESC Heart Failure, 2026. Verfasst von Michael Melin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Heart and Vascular and Neuro Theme, Division of Cardiology, Karolinska University Hospital, Stockholm, Sweden. Hauptthemen laut MEDLINE: Cardiac Output, Vascular Resistance, Hemodynamics, Hypertension, Pulmonary. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The direct Fick method is the gold standard for measuring cardiac output (Q). However, thermodilution (TD) is more widely used in clinical practice due to its feasibility. As the accuracy of TD-derived Q (QTD) may vary by flow state, it can influence the estimation of pulmonary vascular resistance (PVR) and pulmonary hypertension (PH) classification. This study aimed to compare QTD with Fick-derived Q (QF) across haemodynamic states and evaluate the clinical reliability of TD-derived PVR (PVRTD).

Methods

We retrospectively analysed 852 right heart catheterizations (2014–22) with simultaneous QTD and QF measurements.

Results

64% of patients had heart failure, and 20% had pulmonary arterial hypertension. QTD correlated strongly with QF (r = 0.78, P < .001) but demonstrated a flow-dependent bias—overestimating Q in low-flow states (+0.1 L/min) and underestimating it in normal/high flow (−0.48 L/min). Despite this, PVRTD accurately identified elevated PVRF at both 2 and 5 Wood unit thresholds (area under the curve = 0.97, P < .001). Agreement between QTD and QF was unaffected by tricuspid regurgitation severity.

Conclusion

Although TD shows a predictable bias across flow states, it remains a clinically reliable method for estimating elevated PVR. These findings support the clinical utility of TD in PH assessment, while emphasizing the need for direct Fick measurement in low-output states—particularly in patients evaluated for advanced therapies such as transplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac OutputVascular ResistanceHemodynamicsHypertension, PulmonaryHeart FailureHumansThermodilutionRetrospective StudiesCardiac CatheterizationFemaleReproducibility of ResultsMaleMiddle AgedAged

Stichwörter der Autor:innen

Cardiac outputFickPulmonary hypertensionPulmonary vascular resistanceThermodilutionTricuspid regurgitation

Autor:innen und Institutionen

  • Heart and Vascular and Neuro Theme, Division of Cardiology, Karolinska University Hospital, Stockholm, Sweden.
  • Department of Laboratory Medicine, Huddinge, Karolinska Institutet, Stockholm, Sweden.
  • Department of Medicine, Solna, Karolinska Institutet, Stockholm, Sweden.
  • Department of Medicine, Huddinge, Karolinska Insitutet, Stockholm, Sweden.

ORCID-Profile: Aristomenis Manouras

Zitieren

APA

Melin, M., Löfman, I. H., Matan, D., Nygren, M., Shahim, B., Lund, L. H., & Manouras, A. (2026). Agreement of thermodilution and direct Fick methods for cardiac output across varying haemodynamic conditions. ESC Heart Failure. https://doi.org/10.1093/eschf/xvaf001

Vancouver

Melin M, Löfman IH, Matan D, Nygren M, Shahim B, Lund LH, et al. Agreement of thermodilution and direct Fick methods for cardiac output across varying haemodynamic conditions. ESC Heart Failure. 2026. doi:10.1093/eschf/xvaf001

BibTeX
@article{Melin2026,
  author = {Melin, Michael and Löfman, Ida Haugen and Matan, Dmitri and Nygren, Magnus and Shahim, Bahira and Lund, Lars H and Manouras, Aristomenis},
  title = {Agreement of thermodilution and direct Fick methods for cardiac output across varying haemodynamic conditions},
  journal = {ESC Heart Failure},
  year = {2026},
  doi = {10.1093/eschf/xvaf001}
}
Kostenlos starten →