Core Laboratory Comparison of Angiography-Derived Indexes of Microvascular Resistance vs Pressure-Wire IMR and Absolute Resistance
JACC: Cardiovascular Interventions · 2026-03 · 19 (6) · 755-772
DOI: 10.1016/j.jcin.2025.10.027 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift JACC: Cardiovascular Interventions, 2026-03. Verfasst von Tsung-Ying Tsai und 17 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan; CORRIB Research Centre for Advanced Imaging and Core Lab, University of …. Hauptthemen laut MEDLINE: Coronary Angiography, Vascular Resistance, Microcirculation, Cardiac Catheterization. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 62 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Coronary microvascular dysfunction should be assessed in patients with angina and nonobstructive coronary arteries. However, established indexes, such as the pressure wire-derived index of microvascular resistance (PW-IMR) and continuous thermodilution-derived absolute hyperemic microvascular resistance (Rmicro) remain underused, driving development of the wire-free angiography-derived index of microvascular resistance (angio-IMR). OBJECTIVES: The aim of this study was to conduct a core laboratory comparison of 5 angio-IMR methods. METHODS: Five angio-IMR methods derived from 3 software platforms (QAngio XA 3D, FlashAngio, and AngioPlus Core) were compared against PW-IMR in 270 patients (274 vessels) and Rmicro in 42 patients (109 vessels) in a blinded fashion. Diagnostic performance was assessed on a per-vessel basis using receiver-operating characteristic (ROC) curves, Bland-Altman plots, and confusion matrices. RESULTS: The median PW-IMR was 19.02 (Q1-Q3: 12.79-28.08), with 81 of 274 vessels (29.6%) having PW-IMR ≥25. The median Rmicro was 387.50 Wood units (WU) (Q1-Q3: 312.00-501.00 WU), with 33 of 109 vessels (30.3%) having Rmicro ≥475 WU. The correlations among angio-IMR, PW-IMR, and Rmicro were poor across all methods. Three of the 5 methodologies overestimated PW-IMR (mean bias -20.72 to -26.36), with all exhibiting large random errors. ROC analysis using angio-IMR for discriminating PW-IMR ≥25 showed areas under the ROC curve ranging from 0.530 to 0.576 (P > 0.05 for all), while 3 methods (methods A, B, and D) showed significantly better areas under the ROC curve to discriminate Rmicro ≥ 475 WU. When using the prespecified angio-IMR ≥25 threshold, only method E demonstrated acceptable accuracies of 61.4% and 62.0% to identify PW-IMR ≥25 and Rmicro ≥475 WU, respectively. CONCLUSIONS: All 5 angio-IMR methods demonstrated poor diagnostic accuracy compared with PW-IMR and Rmicro, highlighting significant limitations in their clinical utility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan; CORRIB Research Centre for Advanced Imaging and Core Lab, University of Galway, Galway, Ireland.
- CORRIB Research Centre for Advanced Imaging and Core Lab, University of Galway, Galway, Ireland; Lithuanian University of Health Sciences, Kaunas, Lithuania.
- Department of Cardiology, Catharina Hospital, Eindhoven, the Netherlands.
- Department of Interventional Cardiology, Institut d'Investigació Biomèdica de Bellvitge, Hospital Universitari de Bellvitge, Universitat de Barcelona, L'Hospitalet de Llobregat, Spain.
- Department of Cardiology, Angiology, and Internal Intensive Medicine, University Hospital Aachen, Aachen, Germany.
- Cardiovascular Center Aalst, OLV Hospital, Aalst, Belgium.
Zitieren
APA
Tsai, T. Y., Aldujeli, A., Keulards, D. C. J., Gomez-Lara, J., Milzi, A., Corradetti, S., Cheng, K. C., De Silva, R., Renkens, M. P. L., Revaiah, P. C., Tobe, A., Miyashita, K., Oshima, A., Garg, S., Damman, P., Pijls, N., Onuma, Y., & Serruys, P. W. (2026). Core Laboratory Comparison of Angiography-Derived Indexes of Microvascular Resistance vs Pressure-Wire IMR and Absolute Resistance. JACC: Cardiovascular Interventions, 19(6), 755-772. https://doi.org/10.1016/j.jcin.2025.10.027
Vancouver
Tsai TY, Aldujeli A, Keulards DCJ, Gomez-Lara J, Milzi A, Corradetti S, et al. Core Laboratory Comparison of Angiography-Derived Indexes of Microvascular Resistance vs Pressure-Wire IMR and Absolute Resistance. JACC: Cardiovascular Interventions. 2026;19(6):755-772. doi:10.1016/j.jcin.2025.10.027
BibTeX
@article{Tsai2026,
author = {Tsai, Tsung-Ying and Aldujeli, Ali and Keulards, Danielle C J and Gomez-Lara, Josep and Milzi, Andrea and Corradetti, Sara and Cheng, Kevin C and De Silva, Ranil and Renkens, Mick P L and Revaiah, Pruthvi C and Tobe, Akihiro and Miyashita, Kotaro and Oshima, Asahi and Garg, Scot and Damman, Peter and Pijls, Nico and Onuma, Yoshinobu and Serruys, Patrick W},
title = {Core Laboratory Comparison of Angiography-Derived Indexes of Microvascular Resistance vs Pressure-Wire IMR and Absolute Resistance},
journal = {JACC: Cardiovascular Interventions},
year = {2026},
volume = {19},
number = {6},
pages = {755--772},
doi = {10.1016/j.jcin.2025.10.027}
}