Fachartikel in der Zeitschrift European Journal of Cardio-Thoracic Surgery, online erschienen am 26.05.2023. Verfasst von Serdar Akansel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charite (DHZC), Berlin, Germany. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Cardiac Surgical Procedures, Mitral Valve Annuloplasty, Heart Valve Prosthesis. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr. METHODS A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed. RESULTS Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior–posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes. CONCLUSIONS 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyCardiac Surgical ProceduresMitral Valve AnnuloplastyHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHumansMitral ValveTricuspid ValveTreatment Outcome

Stichwörter der Autor:innen

Image-based ring sizingMitral valve repairRing annuloplastyRing size predictionRing sizing

Autor:innen und Institutionen

  • Department of Cardiothoracic and Vascular Surgery, Deutsches Herzzentrum der Charite (DHZC), Berlin, Germany.
  • Department of Cardiovascular Surgery, Charité-Universitätsmedizin Berlin, Berlin, Germany.
  • DZHK (German Center of Cardiovascular Research), Partner Site Berlin, Berlin, Germany.
  • Department of Anesthesiology, Deutsches Herzzentrum der Charite (DHZC), Berlin, Germany.
  • Department of Health Sciences and Technology, ETH Zurich, Zürich, Switzerland.

ORCID-Profile: Serdar Akansel, Markus Kofler, Karel M Van Praet, Simon H Sündermann, Marian Kukucka, Stephan Jacobs, Volkmar Falk, Jörg Kempfert

Zitieren

APA

Akansel, S., Kofler, M., Van Praet, K. M., Sündermann, S. H., Kukucka, M., Jacobs, S., Falk, V., & Kempfert, J. (2023). Image-based ring size prediction for mitral valve repair. European Journal of Cardio-Thoracic Surgery, 64(1). https://doi.org/10.1093/ejcts/ezad212

Vancouver

Akansel S, Kofler M, Van Praet KM, Sündermann SH, Kukucka M, Jacobs S, et al. Image-based ring size prediction for mitral valve repair. European Journal of Cardio-Thoracic Surgery. 2023;64(1). doi:10.1093/ejcts/ezad212

BibTeX
@article{Akansel2023,
  author = {Akansel, Serdar and Kofler, Markus and Van Praet, Karel M and Sündermann, Simon H and Kukucka, Marian and Jacobs, Stephan and Falk, Volkmar and Kempfert, Jörg},
  title = {Image-based ring size prediction for mitral valve repair},
  journal = {European Journal of Cardio-Thoracic Surgery},
  year = {2023},
  volume = {64},
  number = {1},
  doi = {10.1093/ejcts/ezad212}
}
Kostenlos starten →