Non-invasive left ventricular pressure-volume loops from cardiovascular magnetic resonance imaging and brachial blood pressure: validation using pressure catheter measurements
European Heart Journal - Imaging Methods and Practice · 08.09.2023 · 1 (2)
DOI: 10.1093/ehjimp/qyad035 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Heart Journal - Imaging Methods and Practice, online erschienen am 25.10.2023. Verfasst von Per M Arvidsson und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, John Radcliffe Hospital, Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, Oxford …. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: British Heart Foundation, Swedish Heart and Lung Foundation, Region of Scania, Sweden, Bundy Academy, Swedish Heart Association, Swedish Society of Cardiology, Lisa och Johan Grönbergs Stiftelse.
Abstract (Originalsprache)
Aims
Left ventricular (LV) pressure-volume (PV) loops provide gold-standard physiological information but require invasive measurements of ventricular intracavity pressure, limiting clinical and research applications. A non-invasive method for the computation of PV loops from magnetic resonance imaging and brachial cuff blood pressure has recently been proposed. Here we evaluated the fidelity of the non-invasive PV algorithm against invasive LV pressures in humans. Methods and results Four heart failure patients with EF < 35% and LV dyssynchrony underwent cardiovascular magnetic resonance (CMR) imaging and subsequent LV catheterization with sequential administration of two different intravenous metabolic substrate infusions (insulin/dextrose and lipid emulsion), producing eight datasets at different haemodynamic states. Pressure-volume loops were computed from CMR volumes combined with (i) a time-varying elastance function scaled to brachial blood pressure and temporally stretched to match volume data, or (ii) invasive pressures averaged from 19 to 30 sampled beats. Method comparison was conducted using linear regression and Bland-Altman analysis. Non-invasively derived PV loop parameters demonstrated high correlation and low bias when compared to invasive data for stroke work (R2 = 0.96, P < 0.0001, bias 4.6%), potential energy (R2 = 0.83, P = 0.001, bias 1.5%), end-systolic pressure-volume relationship (R2 = 0.89, P = 0.0004, bias 5.8%), ventricular efficiency (R2 = 0.98, P < 0.0001, bias 0.8%), arterial elastance (R2 = 0.88, P = 0.0006, bias −8.0%), mean external power (R2 = 0.92, P = 0.0002, bias 4.4%), and energy per ejected volume (R2 = 0.89, P = 0.0001, bias 3.7%). Variations in estimated end-diastolic pressure did not significantly affect results (P > 0.05 for all). Intraobserver analysis after one year demonstrated 0.9–3.4% bias for LV volumetry and 0.2–5.4% for PV loop-derived parameters.
Conclusion
Pressure-volume loops can be precisely and accurately computed from CMR imaging and brachial cuff blood pressure in humans.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, John Radcliffe Hospital, Oxford Centre for Clinical Magnetic Resonance Research, University of Oxford, Oxford OX3 9DU, United Kingdom.
- Oxford Heart Centre, John Radcliffe Hospital, Oxford OX3 9DU, United Kingdom.
- Department of Physiology, Anatomy and Genetics, University of Oxford, Oxford OX1 3PT, United Kingdom.
- Department of Cardiovascular Medicine, Heart and Lung Research Institute, Papworth Road, Cambridge CB2 0AY, United Kingdom.
- Cardiology Department, Buckinghamshire Healthcare NHS Trust, Wycombe Hospital, Queen Alexandra Road, High Wycombe HP11 2TT, United Kingdom.
- Heart Transplant Department, Harefield Hospital, Royal Brompton and Harefield Hospitals, Hill End Road, Harefield UB9 6JH, United Kingdom.
ORCID-Profile: Per M Arvidsson, Mayooran Shanmuganathan, Einar Heiberg, Håkan Arheden, Neil Herring
Förderung
- British Heart Foundation
- Swedish Heart and Lung Foundation
- Region of Scania, Sweden, Bundy Academy, Swedish Heart Association, Swedish Society of Cardiology, Lisa och Johan Grönbergs Stiftelse
- Swedish Society for Clinical Physiology
- British Heart Foundation Senior Clinical Research Fellowships
Zitieren
APA
Arvidsson, P. M., Green, P. G., Watson, W. D., Shanmuganathan, M., Heiberg, E., De Maria, G. L., Arheden, H., Herring, N., & Rider, O. J. (2023). Non-invasive left ventricular pressure-volume loops from cardiovascular magnetic resonance imaging and brachial blood pressure: validation using pressure catheter measurements. European Heart Journal - Imaging Methods and Practice, 1(2). https://doi.org/10.1093/ehjimp/qyad035
Vancouver
Arvidsson PM, Green PG, Watson WD, Shanmuganathan M, Heiberg E, De Maria GL, et al. Non-invasive left ventricular pressure-volume loops from cardiovascular magnetic resonance imaging and brachial blood pressure: validation using pressure catheter measurements. European Heart Journal - Imaging Methods and Practice. 2023;1(2). doi:10.1093/ehjimp/qyad035
BibTeX
@article{Arvidsson2023,
author = {Arvidsson, Per M and Green, Peregrine G and Watson, William D and Shanmuganathan, Mayooran and Heiberg, Einar and De Maria, Giovanni Luigi and Arheden, Håkan and Herring, Neil and Rider, Oliver J},
title = {Non-invasive left ventricular pressure-volume loops from cardiovascular magnetic resonance imaging and brachial blood pressure: validation using pressure catheter measurements},
journal = {European Heart Journal - Imaging Methods and Practice},
year = {2023},
volume = {1},
number = {2},
doi = {10.1093/ehjimp/qyad035}
}
EUVIMED