Non‐invasive pressure–volume loop analysis in left ventricular load manipulation
Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)
DOI: 10.1111/cpf.70081 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 13.07.2026. Verfasst von Karin Pola und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences, Lund, Clinical Physiology, Skåne University Hospital Lund, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Ventricular Function, Left, Ventricular Pressure, Cardiomyopathy, Hypertrophic, Stroke Volume. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hjärt-Lungfonden, Region Skåne, NIHR Oxford Biomedical Research Centre.
Abstract (Originalsprache)
Background
Clinical monitoring of patients with heart failure or cardiomyopathy is facilitated by detailed assessment of cardiac loading conditions. Specifically, alterations in preload and afterload may unmask pathology through effects on ventricular pressure–volume (PV) relations. Therefore, the aim was to assess non‐invasive PV loops during left ventricular load manipulation in healthy participants and in patients with hypertrophic cardiomyopathy (HCM).
Methods
In total, n = 46 participants were studied in paired experiments at baseline and during load manipulation. Controls ( n = 24) and patients with HCM ( n = 14) were assessed at baseline and during intravenous infusion of 1.5–2 L isotonic saline, and another group of volunteers ( n = 8) was assessed at baseline and during infusion of glyceryl trinitrate (GTN). Non‐invasive PV loops were calculated from cardiovascular magnetic resonance (CMR) and concurrent brachial blood‐pressure measurements.
Results
Saline infusion brought about increased end‐diastolic and decreased end‐systolic volumes in controls, but not in HCM. Concurrently, PV loops revealed mechanistic differences, where controls but not HCM exhibited decreased arterial elastance and potential energy during load manipulation. In both groups, ventricular‐arterial coupling (VAC) decreased, and ventricular efficiency and cardiac output increased. Infusion of GTN resulted in decreased ventricular volumes. Contrary to saline infusion, volunteers receiving GTN retained unchanged arterial elastance, VAC, ventricular efficiency and cardiac output.
Conclusion
Non‐invasive PV analysis from CMR detects cardiac response to altered loading conditions in healthy participants and in patients with HCM. Our findings support the use of CMR‐derived PV loops for detailed assessment of cardiac thermodynamic performance in relation to interventions affecting preload and afterload.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Sciences, Lund, Clinical Physiology, Skåne University Hospital Lund, Lund University, Lund, Sweden.
- Cardiology, Department of Clinical Sciences, Lund, Lund University, Lund, Sweden.
- Department of Cardiology, The Heart Center, Copenhagen University Hospital Rigshospitalet, Copenhagen, Denmark.
- Division of Cardiovascular Medicine, University of Cambridge, Cambridge, UK.
- Oxford Centre for Magnetic Resonance Research, University of Oxford, Oxford, UK.
- Department of Physiology, Anatomy and Genetics, University of Oxford, Oxford, UK.
ORCID-Profile: Karin Pola, Per M Arvidsson
Förderung
- Hjärt-Lungfonden
- Region Skåne
- NIHR Oxford Biomedical Research Centre
- Maggie Stephens Foundation
- Vetenskapsrådet
- Wellcome Career Development Award fellowship
- Wellcome Trust
- Stiftelsen Bundy Academy
Zitieren
APA
Pola, K., Burup Kristensen, C., Watson, W. D., Green, P. G., Raman, B., Neubauer, S., Rider, O. J., Hassager, C., Møgelvang, R., & Arvidsson, P. M. (2026). Non‐invasive pressure–volume loop analysis in left ventricular load manipulation. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70081
Vancouver
Pola K, Burup Kristensen C, Watson WD, Green PG, Raman B, Neubauer S, et al. Non‐invasive pressure–volume loop analysis in left ventricular load manipulation. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70081
BibTeX
@article{Pola2026,
author = {Pola, Karin and Burup Kristensen, Charlotte and Watson, William D and Green, Peregrine G and Raman, Betty and Neubauer, Stefan and Rider, Oliver J and Hassager, Christian and Møgelvang, Rasmus and Arvidsson, Per M},
title = {Non‐invasive pressure–volume loop analysis in left ventricular load manipulation},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
volume = {46},
number = {4},
doi = {10.1111/cpf.70081}
}
EUVIMED