EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

Near Real-Time Multi-Class Segmentation for Intravascular Optical Coherence Tomography using Knowledge Distillation

Ruben G A van der Waerden, Rick H J A Volleberg, Pierandrea Cancian, Joske L van der Zande, Thijs J Luttikholt, Xiaojin Gu, Leah Heil, Jan-Quinten Mol, Kensuke Nishimiya, Tomasz Roleder, Clara I Sánchez, Bram van Ginneken, Jos Thannhauser, Niels van Royen, Ivana Išgum, Simone Saitta

European Heart Journal - Digital Health · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Abstract Aims Intravascular optical coherence tomography (OCT) enables high-resolution imaging of the coronary vessel wall, but manual image interpretation is time-consuming and existing automated approaches often require high computational resources and exhibit slow inference times, limiting clinical use. We developed OCT-AID-lite, a neural network for near real-time multi-class OCT segmentation leveraging knowledge distillation and semi-supervised learning to accelerate inference while maintaining segmentation accuracy. Methods and results A state-of-the-art model (OCT-AID) guided a compact U-Net–based student model (OCT-AID-lite) through knowledge distillation-based supervision. OCT-AID-lite was trained on 3,466 manually annotated and 137,961 pseudo-labeled frames after automated quality control. On 389 internal test frames, OCT-AID-lite achieved a forward-pass time of 0.10 seconds for a 540-frame pullback, compared with 24.22 seconds for OCT-AID model (p<0.01). Including pre- and post-processing, total processing time was 5.50 seconds for OCT-AID-lite, compared with 30.62 seconds for OCT-AID (p<0.01). For lipid and calcium plaque classification, OCT-AID-lite reached sensitivity/specificity of 98.1%/74.4% and 89.5%/87.5%, respectively. Pixel-wise segmentation performance on true-positive frames was high for guidewire, catheter, lumen, intima, and media (Dice: 0.79–0.99), moderate to high for sidebranch, lipid, and calcium (Dice: 0.76–0.78), and more variable for rare complex classes (Dice: 0.39–0.67). On an independent external test set, model predictions were in agreement with expert assessment. Conclusions OCT-AID-lite enables accurate OCT segmentation in near real-time, allowing efficient quantitative characterization of plaque and vessel structures.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Ruben G A van der Waerden, Rick H J A Volleberg, Pierandrea Cancian, Joske L van der Zande, Thijs J Luttikholt, Xiaojin Gu, Leah Heil, Jan-Quinten Mol, Kensuke Nishimiya, Tomasz Roleder, Clara I Sánchez, Bram van Ginneken, Jos Thannhauser, Niels van Royen, Ivana Išgum, Simone Saitta
Quelle
European Heart Journal - Digital Health
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2634-3916
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Ruben G A van der Waerden, Rick H J A Volleberg, Pierandrea Cancian, Joske L van der Zande, Thijs J Luttikholt, Xiaojin Gu, Leah Heil, Jan-Quinten Mol, Kensuke Nishimiya, Tomasz Roleder, Clara I Sánchez, Bram van Ginneken, Jos Thannhauser, Niels van Royen, Ivana Išgum, Simone Saitta (2026). Near Real-Time Multi-Class Segmentation for Intravascular Optical Coherence Tomography using Knowledge Distillation. European Heart Journal - Digital Health. https://doi.org/10.1093/ehjdh/ztag138
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1