Fachartikel in der Zeitschrift European Heart Journal - Cardiovascular Imaging, 2025. Verfasst von Cvetan Trpkov und 16 weiteren Autor:innen. Beteiligte Einrichtung: UBC Centre for Cardiovascular Innovation-Centre d'Innovation Cardiovasculaire, Life Sciences Centre, 2350 Health Sciences Mall, University of British…. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Heart Valve Prosthesis Implantation, Echocardiography, Transesophageal, Mitral Valve Insufficiency. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The mitral valve-in-valve (MVIV) procedure has emerged as an important therapy in failing surgical bioprosthetic valves. We aimed to evaluate factors associated with outcome following MVIV intervention, specifically the impact of 30-day MVIV gradient. We also explored the value of intraprocedural MVIV three-dimensional anatomic orifice area (3D-AOA) by transoesophageal echocardiography in a subset of patients (n = 68). Methods and results Consecutive MVIV patients from a single institution with 30-day transthoracic echocardiography (TTE) were included (N = 100). Clinical and echocardiographic variables were evaluated. The primary outcome was one-year composite of all-cause mortality, heart failure hospitalization or re-intervention. Multivariable analysis was performed to determine predictors of primary outcome. Mean age was 77.3 ± 10.6 years and pre-intervention mean mitral gradient was 11.5 ± 4.0 mmHg. Thirty-day MVIV mean gradient was 7.4 ± 2.6 mmHg with ≤1+ residual regurgitation in 99.0% of patients. Multivariable analysis identified MVIV mean gradient as the only independent determinant of the primary outcome (HR 1.31, CI: 1.07–1.61, P = 0.009). MVIV 3D-AOA was associated with a 30-day MVIV mean gradient of >7 mmHg by TTE (ROC-AUC 0.8, P < 0.001), and patients with 3D-AOA > 2 cm2 had significantly lower 1-year all-cause mortality (2.5% vs. 18.7%, Kaplan–Meier log-rank P = 0.03).

Conclusion

Elevated 30-day mean gradient is associated with worse outcomes after MVIV, and smaller intraprocedural MVIV 3D-AOA is associated with a higher 30-day mean gradient and worse mortality. Optimizing MVIV orifice area at the time of procedure may improve valve haemodynamics and patient outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, Three-DimensionalHeart Valve Prosthesis ImplantationEchocardiography, TransesophagealMitral Valve InsufficiencyHeart Valve ProsthesisBioprosthesisCardiac CatheterizationMitral ValveHumansMaleFemaleAgedTreatment OutcomeAged, 80 and overRetrospective StudiesRisk AssessmentProsthesis Failure

Stichwörter der Autor:innen

3D echocardiography3D mitral valve areainterventional echocardiographymitral valve mean gradientmitral valve-in-valvestructural echocardiography

Autor:innen und Institutionen

  • UBC Centre for Cardiovascular Innovation-Centre d'Innovation Cardiovasculaire, Life Sciences Centre, 2350 Health Sciences Mall, University of British Columbia, Vancouver, BC, Canada V6T 1Z3.
  • Centre for Heart Valve Innovation, St Paul's and Vancouver General Hospitals, University of British Columbia, 1081 Burrard Street, Vancouver, British Columbia, Canada V6Z 1Y6.
  • Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation, University of British Columbia & St. Paul's Hospital, Vancouver, Canada.

ORCID-Profile: Aaisha Ferkh, Robert Moss, Kevin Ong, Jian Ye, Gnalini Sathananthan

Zitieren

APA

Trpkov, C., Ferkh, A., Akodad, M., Chiang, B., Chatfield, A., Meier, D., Jelisejevas, J., Chang, S. A., Moss, R., Ong, K., Sathananthan, J., Wood, D. A., Cheung, A., Ye, J., Yu, M., Webb, J., & Sathananthan, G. (2025). Clinical impact of residual gradient and 3D orifice area after transcatheter mitral valve-in-valve implantation. European Heart Journal - Cardiovascular Imaging. https://doi.org/10.1093/ehjci/jeaf152

Vancouver

Trpkov C, Ferkh A, Akodad M, Chiang B, Chatfield A, Meier D, et al. Clinical impact of residual gradient and 3D orifice area after transcatheter mitral valve-in-valve implantation. European Heart Journal - Cardiovascular Imaging. 2025. doi:10.1093/ehjci/jeaf152

BibTeX
@article{Trpkov2025,
  author = {Trpkov, Cvetan and Ferkh, Aaisha and Akodad, Mariama and Chiang, Brian and Chatfield, Andrew and Meier, David and Jelisejevas, Julius and Chang, Soohyun A and Moss, Robert and Ong, Kevin and Sathananthan, Janarthanan and Wood, David A and Cheung, Anson and Ye, Jian and Yu, Maggie and Webb, John and Sathananthan, Gnalini},
  title = {Clinical impact of residual gradient and 3D orifice area after transcatheter mitral valve-in-valve implantation},
  journal = {European Heart Journal - Cardiovascular Imaging},
  year = {2025},
  doi = {10.1093/ehjci/jeaf152}
}
Kostenlos starten →