Craniofacial measurements using zero echo time magnetic resonance imaging
Dentomaxillofacial Radiology · 2026
DOI: 10.1093/dmfr/twag009 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, 2026. Verfasst von Yuka Uchimoto und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology, Graduate School of Dentistry, The University of Osaka, Suita, Osaka 565-0871, Japan. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cephalometry, Imaging, Three-Dimensional, Facial Bones. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
Objectives
Radiation exposure remains a major concern in dentomaxillofacial imaging, especially for children and young adults who require repeated examinations. A precise, non-ionizing alternative for craniofacial measurement would have significant implications for clinical practice. Computed tomography (CT) and cephalometry are widely used but expose patients to ionizing radiation. Zero Echo Time Magnetic Resonance Imaging (ZTE-MRI) enables visualization of short-T2 tissues, including cortical bone, without radiation by minimizing TE towards zero; however, clinical head-and-neck use has been limited. The goal of the present study was to investigate the possibility of performing precise 3D measurements of the craniofacial regions using ZTE-MRI.
Methods
Twenty-nine participants (mean age 32.14 ± 17.09 years; 23 female, 6 male) underwent MDCT and ZTE-MRI. Standard cephalometric landmarks were identified, yielding 27 linear and 21 angular variables. For each variable, linear regression analysis was performed for the results on MDCT (Multi-Detector CT) images and ZTE-MRI.
Results
Nineteen linear and eight angular variables had regression coefficients between 0.9 and 1.1, and 28 of the linear and 16 of the angular variables had R2 values of 0.81 or higher. Twenty-five linear and 16 angular variables showed Cohen’s effect sizes within the ±0.8 range.
Conclusions
Variables derived from skeletal reference points showed clinically acceptable results, indicating that ZTE-MRI is useful for these measurements. In contrast, variables involving dental reference points demonstrated lower agreement, making accurate measurement in these regions difficult. Advances in knowledge To our knowledge, this study is the first to show that ZTE-MRI allows feasible linear and angular craniofacial measurements used in dental practice and demonstrates good agreement with MDCT for major skeletal landmarks. These findings support its potential future clinical applicability for radiation-free bone assessment; however, further research is warranted to establish its performance across all measurements.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Radiology, Graduate School of Dentistry, The University of Osaka, Suita, Osaka 565-0871, Japan.
- Department of Pediatric Dentistry and Clinical Genetics, School of Dentistry, Faculty of Health and Medical Sciences, University of Copenhagen, DK-2200 Copenhagen, Denmark.
- 3D-Craniofacial Image Research Laboratory, Copenhagen University Hospital, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, DTU informatics, Nørre Allé 20, Copenhagen, DK-2200, Denmark.
- Department of Oral and Maxillofacial Surgery, Copenhagen University Hospital Rigshospitalet, DK-2100 Copenhagen, Denmark.
- Section of Oral and Maxillofacial Radiology, UCLA School of Dentistry, Los Angeles, CA 90095-1668, United States.
- Department of Foreign Languages and Literature, National Tsing Hua University, East District Hsinchu 300013, Taiwan.
ORCID-Profile: Yuka Uchimoto, Sven Kreiborg, Sanjay M Mallya, Shumei Murakami
Zitieren
APA
Uchimoto, Y., Munshi, M. Z. B., Sasai, T., Kreiborg, S., Mallya, S. M., Yang, F. G., & Murakami, S. (2026). Craniofacial measurements using zero echo time magnetic resonance imaging. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twag009
Vancouver
Uchimoto Y, Munshi MZB, Sasai T, Kreiborg S, Mallya SM, Yang FG, et al. Craniofacial measurements using zero echo time magnetic resonance imaging. Dentomaxillofacial Radiology. 2026. doi:10.1093/dmfr/twag009
BibTeX
@article{Uchimoto2026,
author = {Uchimoto, Yuka and Munshi, Maziahtul Zawani Binti and Sasai, Tadashi and Kreiborg, Sven and Mallya, Sanjay M and Yang, Fan-Pei Gloria and Murakami, Shumei},
title = {Craniofacial measurements using zero echo time magnetic resonance imaging},
journal = {Dentomaxillofacial Radiology},
year = {2026},
doi = {10.1093/dmfr/twag009}
}
EUVIMED