Assessment of mandibular landmark specification: correspondence between 2-dimensional radiography and 3-dimensional computed tomography
Dentomaxillofacial Radiology · 2025
DOI: 10.1093/dmfr/twaf020 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, 2025. Verfasst von Misato Shimizu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Maxillofacial Neck Reconstruction, Department of Maxillofacial Orthognathics, Graduate School of Medical and Dental Sciences, Tokyo Medic…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Cephalometry, Mandible, Anatomic Landmarks. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Grants-in-Aid for Scientific Research, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
Objectives
This study aimed to establish accurate correspondence between landmarks on lateral (LA) and posteroanterior (PA) cephalograms and to demonstrate the locational relationship of these landmarks in 2-dimensional (2D) and 3-dimensional (3D) images.
Methods
Twenty patients with skeletal Class III jaw deformity, without significant facial asymmetry, were recruited for this study. LA and PA cephalograms, taken simultaneously just before the orthognathic surgery, were utilized. Twelve mandibular landmarks were identified on each cephalogram, and their 3D coordinates values, as well as the residual differences between LA and PA cephalograms were calculated. To clarify the geometric correspondence between the LA and PA landmarks, the epipolar line method was introduced, which aimed to reduce residuals. In addition, 3D coordinate values of landmarks were compared between cephalograms and CT images in 5 patients with minimal asymmetry, by measuring the distance between corresponding landmarks as an error metric.
Results
The use of epipolar lines significantly reduced the residuals for 3D coordinates across all landmarks compared to those without epipolar lines. In comparison of 3D coordinate values between cephalograms and CT images, the average error across all landmarks was approximately 0.64 mm, which was lower than reported in previous study.
Conclusions
Incorporating epipolar lines during landmark extraction from LA and PA cephalograms significantly improved the accuracy and reliability of landmark correspondence between the 2 cephalograms. The 3D coordinate values derived from cephalograms closely matched those obtained from CT images, demonstrating high accuracy although they were independently derived.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Maxillofacial Neck Reconstruction, Department of Maxillofacial Orthognathics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo 113-8549, Japan.
- Department of Biomedical Information, Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Tokyo 101-0062, Japan.
ORCID-Profile: Yoshikazu Nakajima, Takeshi Ogasawara, Masayoshi Uezono, Keiji Moriyama
Förderung
- Grants-in-Aid for Scientific Research
- Japan Society for the Promotion of Science
Zitieren
APA
Shimizu, M., Nakajima, Y., Ogasawara, T., Uezono, M., & Moriyama, K. (2025). Assessment of mandibular landmark specification: correspondence between 2-dimensional radiography and 3-dimensional computed tomography. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twaf020
Vancouver
Shimizu M, Nakajima Y, Ogasawara T, Uezono M, Moriyama K. Assessment of mandibular landmark specification: correspondence between 2-dimensional radiography and 3-dimensional computed tomography. Dentomaxillofacial Radiology. 2025. doi:10.1093/dmfr/twaf020
BibTeX
@article{Shimizu2025,
author = {Shimizu, Misato and Nakajima, Yoshikazu and Ogasawara, Takeshi and Uezono, Masayoshi and Moriyama, Keiji},
title = {Assessment of mandibular landmark specification: correspondence between 2-dimensional radiography and 3-dimensional computed tomography},
journal = {Dentomaxillofacial Radiology},
year = {2025},
doi = {10.1093/dmfr/twaf020}
}
EUVIMED