EUVIMEDEUVIMED entdecken
Crossref

Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information

Jennifer Christensen iD, Louise Hauge Matzen, Mette Hedegaard, Rubens Spin-Neto

Dentomaxillofacial Radiology · 2024

DOI: 10.1093/dmfr/twae039 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, 2024. Verfasst von Jennifer Christensen und 3 weiteren Autor:innen. Beteiligte Einrichtung: Section for Oral Radiology and Endodontics, Aarhus University, Aarhus 8000, Denmark. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography. Die Arbeit nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of the present study was to assess the reproducibility of findings in cone beam CT (CBCT) scout images. Furthermore, the study aimed to assess whether a scout image shows pathology not seen within the CBCT volume (ie, added diagnostic information) and therefore must be assessed on the same terms as the full volume.

Methods

Using a retrospective design, 233 CBCT reports and scout images were assessed. Kappa statistics and percentage of accordance were used to evaluate intra- and inter-observer reproducibility as well as agreement between scout and CBCT report.

Results

Intra- and inter-observer reproducibility was overall low (kappa ranging from −0.008 to 1.000). Agreement between findings reported in the CBCT and scout was also low. One hundred fourteen impacted teeth, one apical periodontitis, and two sinus conditions seen in the scout image were not registered in the full volume report due to the extended size of the scout image.

Conclusions

Reproducibility of findings in scout images compared to CBCT volumes was low, and the scout showed very little additional diagnostic information. Advances in knowledge This study shows that although the reproducibility of viewing scout images is low, rare findings can go undetected if the scout is not assessed. Legislation regarding interpretation of scout images needs to be discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyHumansReproducibility of ResultsRetrospective StudiesFemaleMaleAdultMiddle AgedAgedObserver VariationAdolescentAged, 80 and over

Stichwörter der Autor:innen

cone beam CTdentistrydiagnosisdiagnostic imaging

Autor:innen und Institutionen

  • Section for Oral Radiology and Endodontics, Aarhus University, Aarhus 8000, Denmark.
  • Section for Orthodontics, Randers Community Dentistry, Randers 8900, Denmark.

ORCID-Profile: Jennifer Christensen

Zitieren

APA

Christensen, J., Matzen, L. H., Hedegaard, M., & Spin-Neto, R. (2024). Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twae039

Vancouver

Christensen J, Matzen LH, Hedegaard M, Spin-Neto R. Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information. Dentomaxillofacial Radiology. 2024. doi:10.1093/dmfr/twae039

BibTeX
@article{Christensen2024,
  author = {Christensen, Jennifer and Matzen, Louise Hauge and Hedegaard, Mette and Spin-Neto, Rubens},
  title = {Scout images acquired prior to cone beam CT acquisitions: reproducibility of findings and added diagnostic information},
  journal = {Dentomaxillofacial Radiology},
  year = {2024},
  doi = {10.1093/dmfr/twae039}
}