Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography
Dentomaxillofacial Radiology · 2024
DOI: 10.1093/dmfr/twae008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Dentomaxillofacial Radiology, 2024. Verfasst von Camila Porto Capel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Artifacts, Dental Implants. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: São Paulo Research Foundation.
Abstract (Originalsprache)
Objectives
This study evaluated the effect of metal artefact reduction (MAR) level and tube current on the assessment of dental implant positioning relative to the mandibular canal (MC) through cone-beam computed tomography (CBCT).
Methods
Titanium dental implants were placed in dried mandibles at 0.5-mm superior to the MC (group 1/n = 8) and 0.5-mm inside the MC with perforation of the cortex (group 2/n = 10). CBCT scans were obtained with different levels of MAR (off, medium, and high) and 2 tube currents (4 and 8 mA). Four examiners analysed the images and scored the contact between the implant and the MC using a 5-point scale. Sensitivity, specificity, area under receiver operating characteristic curve (ROC), and frequency of scores were calculated. Data were compared with analysis of variance 2-way and Tukey's test and scores with Chi-square test.
Results
Specificity and area under ROC curve decreased significantly when MAR level was high compared with MAR-medium and MAR-off. The frequency of score 3 (inconclusive) was the highest, and scores 1 and 5 (definitely no contact and definitely contact, respectively) were the lowest with MAR-high, regardless of the tube current. When MAR was off, there were higher frequencies of scores 1 and 5.
Conclusions
The level of MAR influences the assessment of the relationship between the dental implant and the MC. MAR-high led to lower diagnostic accuracy compared with MAR-medium and off. Advances in knowledge This article shows that high level of MAR can interfere in the diagnostic of dental implant positioning relative to the MC, decreasing its accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Dental Materials and Prosthodontics, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.
- Department of Dentistry and Oral Health, Aarhus University, 8000 Aarhus, Denmark.
- Department of Radiology, Faculty of Dentistry, Chulalongkorn University, 10330 Bangkok, Thailand.
- Department of Stomatology, Public Health and Forensic Dentistry, Ribeirão Preto School of Dentistry, University of São Paulo, 14040-904, São Paulo, Brazil.
- Department of Diagnosis & Oral Health, University of Louisville, School of Dentistry, 40202-1701, Louisville, KY, United States.
ORCID-Profile: Camila Porto Capel, Raphael Jurca Gonçalves da Motta, Ruben Pauwels, Christiano Oliveira-Santos, Camila Tirapelli
Förderung
- São Paulo Research Foundation
Zitieren
APA
Capel, C. P., da Motta, R. J. G., Pauwels, R., Gaêta-Araujo, H., Oliveira-Santos, C., & Tirapelli, C. (2024). Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography. Dentomaxillofacial Radiology. https://doi.org/10.1093/dmfr/twae008
Vancouver
Capel CP, da Motta RJG, Pauwels R, Gaêta-Araujo H, Oliveira-Santos C, Tirapelli C. Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography. Dentomaxillofacial Radiology. 2024. doi:10.1093/dmfr/twae008
BibTeX
@article{Capel2024,
author = {Capel, Camila Porto and da Motta, Raphael Jurca Gonçalves and Pauwels, Ruben and Gaêta-Araujo, Hugo and Oliveira-Santos, Christiano and Tirapelli, Camila},
title = {Effect of metal artefact reduction level on the assessment of dental implant positioning by cone-beam computed tomography},
journal = {Dentomaxillofacial Radiology},
year = {2024},
doi = {10.1093/dmfr/twae008}
}
EUVIMED