Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants

Hideki Suito iD, Hozumi Yoshihara iD, Naoki Maeda iD, Ryosuke Kasai iD, Tadashi Inoue iD, Masafumi Amano iD, Yuuri Oku iD, Keiko Fujimoto iD, Kan Nagao iD

Oral Radiology · 2025

DOI: 10.1007/s11282-025-00814-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Oral Radiology, 2025. Verfasst von Hideki Suito und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Radiology, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima, 770-8504, …. Hauptthemen laut MEDLINE: Artifacts, Titanium, Zirconium, Dental Implants. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: Zirconia oral implants produce larger artifacts on computed tomography (CT) compared to titanium oral implants. This study aimed to compare the effectiveness of metal artifact reduction (MAR) software and dual-energy (DE) methods, which are used in multi-detector CT (MDCT) to reduce the artifacts produced by titanium and zirconia oral implants. METHODS: Oral implants were placed in the lower right second premolar and second molar regions of an acrylic mandible model and evaluated using MDCT. For MAR, Single Energy Metal Artifact Reaction (SEMAR) images were obtained, and for DE, images were obtained at 135 keV. The evaluation was based on 21 regions of interest (ROIs) with sides of 2.8 mm, set at 15, 25, and 35 mm from the center (the lower-right first premolar), with 65°, 90°, 115°, and 145° angles set on the buccal and lingual sides. The evaluation was based on an Artifact Index (AI). RESULTS: The lingual aspect of the AI tended to be larger compared to the buccal aspect, regardless of the image-processing method. In addition, the SEMAR method tended to have a greater artifact reduction effect than the DE method. The distortion of the mandibular model and occurrence of new artifacts were confirmed using SEMAR. CONCLUSIONS: SEMAR had higher artifact reduction effects on metal artifacts than the DE method. Although SEMAR and dual-energy methods can effectively reduce metal artifacts, they also cause false images and areas that cannot be observed. Therefore, diagnostic and treatment planning, including imaging, is essential before artifact reduction processing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsTitaniumZirconiumDental ImplantsMultidetector Computed TomographyHumansMetalsMandible

Stichwörter der Autor:innen

Computed tomographyDual-energyMetal artifact reductionTitanium implantZirconia implant

Substanzen

TitaniumZirconiumDental Implantszirconium oxideMetals

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Radiology, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima, 770-8504, Japan. suito.hideki@tokushima-u.ac.jp.
  • Department of Oral and Maxillofacial Radiology, Graduate School of Biomedical Sciences, Tokushima University, 3-18-15 Kuramoto, Tokushima, 770-8504, Japan.
  • Department of Medical Imaging/Nuclear Medicine, Graduate School of Biomedical Sciences, Tokushima University, Tokushima, Japan.
  • Department of Clinical Technology, Division of Radiology, Tokushima University Hospital, Tokushima, Japan.
  • Department of Prosthodontics and Oral Rehabilitation, Graduate School of Biomedical Sciences, Tokushima University, Tokushima, Japan.

ORCID-Profile: Hideki Suito, Hozumi Yoshihara, Naoki Maeda, Ryosuke Kasai, Tadashi Inoue, Masafumi Amano, Yuuri Oku, Keiko Fujimoto, Kan Nagao

Zitieren

APA

Suito, H., Yoshihara, H., Maeda, N., Kasai, R., Inoue, T., Amano, M., Oku, Y., Fujimoto, K., & Nagao, K. (2025). Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants. Oral Radiology. https://doi.org/10.1007/s11282-025-00814-5

Vancouver

Suito H, Yoshihara H, Maeda N, Kasai R, Inoue T, Amano M, et al. Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants. Oral Radiology. 2025. doi:10.1007/s11282-025-00814-5

BibTeX
@article{Suito2025,
  author = {Suito, Hideki and Yoshihara, Hozumi and Maeda, Naoki and Kasai, Ryosuke and Inoue, Tadashi and Amano, Masafumi and Oku, Yuuri and Fujimoto, Keiko and Nagao, Kan},
  title = {Evaluation of the effect of reducing metal artifacts in multi-detector CT imaging of zirconia and titanium implants},
  journal = {Oral Radiology},
  year = {2025},
  doi = {10.1007/s11282-025-00814-5}
}
Kostenlos starten →