EUVIMEDEUVIMED entdecken
Crossref

Pathophysiological Responses to Bloodstream Infection in Critically Ill Transplant Recipients Compared With Non-Transplant Recipients

Jiaxing Qiu, Alex N Zimmet, Taison D Bell, Shrirang Gadrey, Jackson Brandberg, Samuel Maldonado, Amanda M Zimmet, Sarah Ratcliffe, Pavel Chernyavskiy, J Randall Moorman, Gilles Clermont, Teague R Henry und 2 weitere

Clinical Infectious Diseases · 2024

DOI: 10.1093/cid/ciad662 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Infectious Diseases, 2024. Verfasst von Jiaxing Qiu und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Division of Cardiovascular Diseases, Center for Advanced Medical Analytics, University of Virginia School of Medicine, Charlo…. Hauptthemen laut MEDLINE: Bacteremia, Sepsis. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Global Infectious Diseases Institute, Center for Engineering in Medicine at the University of Virginia.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Identification of bloodstream infection (BSI) in transplant recipients may be difficult due to immunosuppression. Accordingly, we aimed to compare responses to BSI in critically ill transplant and non-transplant recipients and to modify systemic inflammatory response syndrome (SIRS) criteria for transplant recipients.

Methods

We analyzed univariate risks and developed multivariable models of BSI with 27 clinical variables from adult intensive care unit (ICU) patients at the University of Virginia (UVA) and at the University of Pittsburgh (Pitt). We used Bayesian inference to adjust SIRS criteria for transplant recipients.

Results

We analyzed 38.7 million hourly measurements from 41 725 patients at UVA, including 1897 transplant recipients with 193 episodes of BSI and 53 608 patients at Pitt, including 1614 transplant recipients with 768 episodes of BSI. The univariate responses to BSI were comparable in transplant and non-transplant recipients. The area under the receiver operating characteristic curve (AUC) was 0.82 (95% confidence interval [CI], .80–.83) for the model using all UVA patient data and 0.80 (95% CI, .76–.83) when using only transplant recipient data. The UVA all-patient model had an AUC of 0.77 (95% CI, .76–.79) in non-transplant recipients and 0.75 (95% CI, .71–.79) in transplant recipients at Pitt. The relative importance of the 27 predictors was similar in transplant and non-transplant models. An upper temperature of 37.5°C in SIRS criteria improved reclassification performance in transplant recipients.

Conclusions

Critically ill transplant and non-transplant recipients had similar responses to BSI. An upper temperature of 37.5°C in SIRS criteria improved BSI screening in transplant recipients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BacteremiaSepsisAdultHumansTransplant RecipientsCritical IllnessBayes TheoremSystemic Inflammatory Response SyndromeRetrospective Studies

Stichwörter der Autor:innen

bloodstream infectioncritical careinflammationsepsistransplant

Autor:innen und Institutionen

  • Department of Medicine, Division of Cardiovascular Diseases, Center for Advanced Medical Analytics, University of Virginia School of Medicine, Charlottesville, Virginia, USA.
  • Department of Medicine, Division of Infectious Diseases and Geographic Medicine, Stanford University School of Medicine, Stanford, California, USA.
  • Department of Medicine, Division of Pulmonary and Critical Care Medicine and Division of Infectious Diseases and International Health, University of Virginia School of Medicine, Charlottesville, Virginia, USA.
  • Department of Medicine, Division of Hospital Medicine, University of Virginia School of Medicine, Charlottesville, Virginia, USA.
  • Department of Medicine, Division of Infectious Diseases, Massachusetts General Hospital, Harvard University School of Medicine, Boston, Massachusetts, USA.
  • Department of Public Health Sciences, University of Virginia School of Medicine, Charlottesville, Virginia, USA.

ORCID-Profile: Christopher C Moore

Förderung

  • Global Infectious Diseases Institute
  • Center for Engineering in Medicine at the University of Virginia

Zitieren

APA

Qiu, J., Zimmet, A. N., Bell, T. D., Gadrey, S., Brandberg, J., Maldonado, S., Zimmet, A. M., Ratcliffe, S., Chernyavskiy, P., Moorman, J. R., Clermont, G., Henry, T. R., Nguyen, N. R., & Moore, C. C. (2024). Pathophysiological Responses to Bloodstream Infection in Critically Ill Transplant Recipients Compared With Non-Transplant Recipients. Clinical Infectious Diseases. https://doi.org/10.1093/cid/ciad662

Vancouver

Qiu J, Zimmet AN, Bell TD, Gadrey S, Brandberg J, Maldonado S, et al. Pathophysiological Responses to Bloodstream Infection in Critically Ill Transplant Recipients Compared With Non-Transplant Recipients. Clinical Infectious Diseases. 2024. doi:10.1093/cid/ciad662

BibTeX
@article{Qiu2024,
  author = {Qiu, Jiaxing and Zimmet, Alex N and Bell, Taison D and Gadrey, Shrirang and Brandberg, Jackson and Maldonado, Samuel and Zimmet, Amanda M and Ratcliffe, Sarah and Chernyavskiy, Pavel and Moorman, J Randall and Clermont, Gilles and Henry, Teague R and Nguyen, N Rich and Moore, Christopher C},
  title = {Pathophysiological Responses to Bloodstream Infection in Critically Ill Transplant Recipients Compared With Non-Transplant Recipients},
  journal = {Clinical Infectious Diseases},
  year = {2024},
  doi = {10.1093/cid/ciad662}
}
Kostenlos starten →