Evaluation of an Intensive Care Unit Sepsis Alert in Critically Ill Medical Patients
American Journal of Critical Care · 2024
DOI: 10.4037/ajcc2024566 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Critical Care, 2024. Verfasst von Rebecca L Rich und 4 weiteren Autor:innen. Beteiligte Einrichtung: Rebecca L. Rich is a critical care clinical pharmacy specialist, Department of Pharmacy, Lakeland Regional Health, Lakeland, Florida. Hauptthemen laut MEDLINE: Intensive Care Units, Critical Illness, Sepsis, Systemic Inflammatory Response Syndrome. Die Arbeit nennt 20 Literaturangaben.
Themen: Intensivpflege, Sepsis
Abstract (Originalsprache)
Background
Sepsis alerts commonly used for intensive care unit (ICU) patients can lead to alert fatigue because these patients generally meet 1 or more of the criteria for systemic inflammatory response syndrome. To identify ICU patients at greatest risk for sepsis-related consequences, an ICU-specific sepsis alert was implemented.
Objective
To evaluate an ICU sepsis alert based on modified criteria for systemic inflammatory response syndrome among critically ill medical patients.
Methods
This retrospective evaluation was conducted at a comprehensive tertiary referral center. Patients included were at least 18 years old, were admitted to the critical care medicine service, and had at least 1 sepsis alert between January 1 and February 29, 2020. The sepsis alert identified patients meeting at least 2 modified systemic inflammatory response syndrome criteria (white blood cell count, <4000/μL or >12 000/μL; body temperature, <36 °C or >38.3 °C; heart rate, >110/min; and respiratory rate, >21/min), with at least 1 of the 2 criteria being white blood cell count or body temperature.
Results
For 128 alerts evaluated, the positive predictive value was 72%. Of 713 patients who were admitted to the critical care medicine service and did not have a sepsis alert, 7 received a sepsis diagnosis. The ICU sepsis alert had a negative predictive value of 99%, sensitivity of 92.9%, and specificity of 95.1%.
Conclusions
An ICU sepsis alert using modified systemic inflammatory response syndrome criteria was effective for identifying sepsis in critically ill medical patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Rebecca L. Rich is a critical care clinical pharmacy specialist, Department of Pharmacy, Lakeland Regional Health, Lakeland, Florida.
- Jennifer M. Montero is a quality clinical pharmacy specialist and sepsis coordinator, Department of Clinical Quality, Lakeland Regional Health.
- Kyle E. Dillon is a critical care clinical pharmacy specialist, Department of Pharmacy, Lakeland Regional Health.
- Patrick Condon is an emergency medicine clinical pharmacy specialist, Department of Pharmacy, Orlando Health, Orlando, Florida.
- Mathew Vadaparampil is a pulmonary critical care intensivist, Department of Critical Care Medicine, Lakeland Regional Health.
Zitieren
APA
Rich, R. L., Montero, J. M., Dillon, K. E., Condon, P., & Vadaparampil, M. (2024). Evaluation of an Intensive Care Unit Sepsis Alert in Critically Ill Medical Patients. American Journal of Critical Care. https://doi.org/10.4037/ajcc2024566
Vancouver
Rich RL, Montero JM, Dillon KE, Condon P, Vadaparampil M. Evaluation of an Intensive Care Unit Sepsis Alert in Critically Ill Medical Patients. American Journal of Critical Care. 2024. doi:10.4037/ajcc2024566
BibTeX
@article{Rich2024,
author = {Rich, Rebecca L and Montero, Jennifer M and Dillon, Kyle E and Condon, Patrick and Vadaparampil, Mathew},
title = {Evaluation of an Intensive Care Unit Sepsis Alert in Critically Ill Medical Patients},
journal = {American Journal of Critical Care},
year = {2024},
doi = {10.4037/ajcc2024566}
}