Aim

The use of cephalomedullary nailing (CMN) to treat extracapsular hip fractures is a well-established fixation method. Nationally, the use of CMN has increased from 67.7% in 2012 to 90.9% in 2025 for subtrochanteric fractures (National Hip Fracture Database). Although rare, implant failure poses risk to patients who are already burdened with high morbidity and mortality. The purpose of this study is to review the outcomes of CMN fixations, analysing patient demographics, focussing on implant failure.

Method

This is a retrospective longitudinal cohort study of CMN fixations at a district general hospital between January 2020 and October 2024. Data collection was obtained from clinical records and imaging. Multivariable logistic regression modelling was performed to analyse results.

Results

Long CMN was used for 208 cases. Of these, the majority were female (74.5%) with a mean age 82 years. Open reduction and augmentation with cerclage wires was used in 27.4% of cases (n=57). Of the 208 CMN cases, an overall failure rate of 4.3% (n=9) was identified. Open reduction and cerclage wire augmentation was associated with higher rates of implant failure (10.5% vs 2.0%, p-value 0.006) when compared to closed reduction alone.

Conclusions

Our findings suggest that our outcomes of CMN fixation are comparable to existing literature. However, we have identified that patients treated with open reduction and cerclage wiring have a 11x higher risk of implant failure. Our unit has since implemented routine follow up and radiographic surveillance at 6 months for all patients treated with long CMN with open reduction and cerclage wire fixation.

Zitieren

APA

Frackelton, R., Moreau, J., Tun, S. M. T., Abed, R., & Brunton, L. (2026). 1245 Factors Influencing Implant Failure in Cephalomedullary Nails for Proximal Femoral Fractures: A Retrospective Review. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.161

Vancouver

Frackelton R, Moreau J, Tun SMT, Abed R, Brunton L. 1245 Factors Influencing Implant Failure in Cephalomedullary Nails for Proximal Femoral Fractures: A Retrospective Review. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.161

BibTeX
@article{Frackelton2026,
  author = {Frackelton, R and Moreau, J and Tun, S M T and Abed, R and Brunton, L},
  title = {1245 Factors Influencing Implant Failure in Cephalomedullary Nails for Proximal Femoral Fractures: A Retrospective Review},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.161}
}
Kostenlos starten →