EUVIMEDEUVIMED entdecken
Crossref

104 Implant Failure After TFNA Intramedullary Nailing for Proximal Femur Fractures: A UK Retrospective Cohort and Literature Review

R Bassi, M S Kim, A Sharma, T Singh, A Kozhikunnath, S Agarwal

British Journal of Surgery · 10.07.2026 · 113 (Supplement_6)

DOI: 10.1093/bjs/znag063.697 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Surgery, online erschienen am 10.07.2026. Verfasst von R Bassi und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Proximal femur fractures impose a major trauma workload, with intramedullary nailing preferred for unstable intertrochanteric and subtrochanteric fractures. The Trochanteric Femoral Nailing Advanced (TFNA) system was developed to enhance fixation stability, but subsequent reports have raised concerns about implant breakage. This study evaluated the rate and mode of TFNA failure in a UK trauma unit and contextualised the findings through a literature review.

Method

A retrospective cohort study was conducted of all adults who underwent TFNA fixation for intertrochanteric or subtrochanteric fractures over a two-year period, excluding prophylactic nailing for pathological lesions. Demographic, operative, and radiological data were obtained from patient records and the National Hip Fracture Database. The primary outcome was implant breakage; secondary outcomes included screw cut-out and non-union. Kaplan–Meier survival and log-rank analyses explored associations between covariates and implant survival.

Results

A total of 216 patients (mean age 81.4 ± 8.9 years) met inclusion criteria. Seven implant failures (3.2%) occurred: three breakages (1.4%), three screw cut-outs (1.4%), and one non-union (0.5%). Mean time to breakage was 354 days and to cut-out 41 days. No significant associations were found between implant survival and age, sex, ASA grade, nail length, or fracture type. Overall implant survival was 96.7%. Reported TFNA breakage rates in the literature ranged from 0% to 4.7%.

Conclusions

The TFNA system demonstrated a 1.4% breakage rate, slightly above the 1.3% benchmark for cephalomedullary nails but within acceptable limits. Findings were consistent with published data, supporting the need for larger multicentre studies with extended follow-up to evaluate long-term durability.

Zitieren

APA

Bassi, R., Kim, M. S., Sharma, A., Singh, T., Kozhikunnath, A., & Agarwal, S. (2026). 104 Implant Failure After TFNA Intramedullary Nailing for Proximal Femur Fractures: A UK Retrospective Cohort and Literature Review. British Journal of Surgery, 113(Supplement_6). https://doi.org/10.1093/bjs/znag063.697

Vancouver

Bassi R, Kim MS, Sharma A, Singh T, Kozhikunnath A, Agarwal S. 104 Implant Failure After TFNA Intramedullary Nailing for Proximal Femur Fractures: A UK Retrospective Cohort and Literature Review. British Journal of Surgery. 2026;113(Supplement_6). doi:10.1093/bjs/znag063.697

BibTeX
@article{Bassi2026,
  author = {Bassi, R and Kim, M S and Sharma, A and Singh, T and Kozhikunnath, A and Agarwal, S},
  title = {104 Implant Failure After TFNA Intramedullary Nailing for Proximal Femur Fractures: A UK Retrospective Cohort and Literature Review},
  journal = {British Journal of Surgery},
  year = {2026},
  volume = {113},
  number = {Supplement_6},
  doi = {10.1093/bjs/znag063.697}
}
Kostenlos starten →