EUVIMEDEUVIMED entdecken
Crossref

Comparative study of dual-energy X‑ray absorptiometry versus multislice computed tomography for vertebral height measurement

Chun-Hsiang Chan, Ai-Ling Hsu, Vu Pham Thao Vy, Yi-Chien Lu, Chih-Hsiang Ko, Shan Chia Wu, Yi-Ping Chao, Truong Nguyen Khanh Hung, Russell O Kosik, Wing P Chan

British Journal of Radiology · 02.11.2026

DOI: 10.1093/bjr/tqag265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, online erschienen am 02.11.2026. Verfasst von Chun-Hsiang Chan und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei 110, Taiwan. Die Arbeit nennt 25 Literaturangaben. Gefördert von: Wan Fang Hospital, Taipei Medical University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study investigates the discrepancies between 2-dimensional (2D) and 3-dimensional (3D) imaging-based approaches for vertebral height assessment.

Methods

Lumbar spine CT scans and dual-energy X‑ray absorptiometry (DXA) studies within 6 months were reviewed. Vertebral fracture assessment was performed by converting CT-measured height ratios into Genant grades using 3 methods: conventional (A), consensus (B), and global search (C). Dataset 1 included 34 patients (191 vertebrae; 1302 CT slices) with CT and DXA; Dataset 2 included 114 patients with CT only.

Results

No significant difference was observed between Method A and DXA-based grading (P = .33). In contrast, Methods B and C significantly differed from DXA (P < .001, both). Discrepancies were greatest for vertebrae graded as 1 by Method A (98 and 166 vertebrae reclassified by Methods B and C, respectively). Compared with Method A, Method B revealed greater height reductions in Grades 0, 1, and 2 vertebrae by 9.00, 9.13, and 13.75 percentage points, respectively. For Method C, these reductions were 10.71, 10.14, and 12.35 percentage points, respectively.

Conclusions

Compared with DXA, continuous sagittal CT images improved detection of greatest vertebral height loss, especially for Grade 1 reductions. When applying 2D criteria to CT scans, clinicians should be cautious of a tendency to overestimate vertebral height loss. Advances in knowledge This first study demonstrates that the 3D method yields vertebral height reduction 10.84 percentage points greater than the 2D method. Therefore, overestimation of vertebral height reduction on CT should be considered when radiological classification criteria are applied.

Schlagwörter

Stichwörter der Autor:innen

Computed tomographycompression fracturedual-energy X‑ray absorptiometryquantitative analysisspine

Autor:innen und Institutionen

  • Department of Radiology, School of Medicine, College of Medicine, Taipei Medical University, Taipei 110, Taiwan.
  • Department of Radiology, Wan Fang Hospital, Taipei Medical University, Taipei 116, Taiwan.
  • Bachelor Program in Artificial Intelligence and Graduate Institute of Artificial Intelligence, Chang Gung University, Taoyuan 333, Taiwan.
  • Department of Psychiatry, Chang Gung Memorial Hospital at Linkou, Taoyuan 333, Taiwan.
  • International PhD Program of Medicine, Taipei Medical University, Taipei 110, Taiwan.
  • Department of Radiology, Thai Nguyen National Hospital, Thai Nguyen 24000, Vietnam.

Förderung

  • Wan Fang Hospital, Taipei Medical University

Zitieren

APA

Chan, C. H., Hsu, A. L., Vy, V. P. T., Lu, Y. C., Ko, C. H., Wu, S. C., Chao, Y. P., Hung, T. N. K., Kosik, R. O., & Chan, W. P. (2026). Comparative study of dual-energy X‑ray absorptiometry versus multislice computed tomography for vertebral height measurement. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag265

Vancouver

Chan CH, Hsu AL, Vy VPT, Lu YC, Ko CH, Wu SC, et al. Comparative study of dual-energy X‑ray absorptiometry versus multislice computed tomography for vertebral height measurement. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag265

BibTeX
@article{Chan2026,
  author = {Chan, Chun-Hsiang and Hsu, Ai-Ling and Vy, Vu Pham Thao and Lu, Yi-Chien and Ko, Chih-Hsiang and Wu, Shan Chia and Chao, Yi-Ping and Hung, Truong Nguyen Khanh and Kosik, Russell O and Chan, Wing P},
  title = {Comparative study of dual-energy X‑ray absorptiometry versus multislice computed tomography for vertebral height measurement},
  journal = {British Journal of Radiology},
  year = {2026},
  doi = {10.1093/bjr/tqag265}
}
Kostenlos starten →