Half-count myocardial imaging on the D-SPECT camera: phantom validation and clinical agreement for perfusion and function
British Journal of Radiology · 2026
DOI: 10.1093/bjr/tqag201 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift British Journal of Radiology, 2026. Verfasst von Sharon Gomez Villegas und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, University of Trieste, Trieste 34127, Italy. Hauptthemen laut MEDLINE: Myocardial Perfusion Imaging, Tomography, Emission-Computed, Single-Photon. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Objectives
To evaluate the accuracy of the cadmium-zinc-telluride (CZT) D-SPECT (Spectrum Dynamics) system in quantifying left ventricle (LV) perfusion and function in 99mTc myocardial perfusion imaging (MPI) at half-count statistics.
Methods
Segmental perfusion, extent and volume of a perfusion defect (PD) were evaluated in an anthropomorphic phantom simulating normal and pathological myocardial condition at the reference 1 million counts (Mc) and at reduced-count statistics (0.8, 0.6, 0.4, 0.25 Mc). Summed stress scores (SSS), summed rest scores (SRS), summed difference score (SDS), total perfusion deficit (TPD), ischemic total perfusion deficit (ITPD), and ejection fraction (EF) were evaluated in 326 MPI patient studies, stratified on the classification of myocardial perfusion and LV ejection fraction (LVEF), at 1 and 0.5Mc statistics.
Results
In the phantom study, the count statistics did not affect mean perfusion and PD extent and volume down to 0.4Mc. In the patient study, high concordance was observed between datasets, with Kw values of 0.846 (SSS), 0.922 (SRS), 0.676 (SDS), and K values of 0.89 (TPD), and 0.70 (ITPD). Bland-Altman analysis showed minimal bias and narrow limits of agreement for LVEF (−0.1%; −6.9% to 6.7%).
Conclusions
The study demonstrated the feasibility of a 50% count reduction for myocardial perfusion imaging performed with the D-SPECT system and the acquisition/reconstruction protocol evaluated in this study, preserving diagnostic accuracy while lowering radiation exposure or acquisition time. Advances in knowledge The ability to maintain diagnostic accuracy with 50% fewer counts supports the adoption of optimized, low-dose single photon emission computed tomography (SPECT) protocols enhancing patient safety and imaging efficiency. This reinforces the role of CZT technology in low-dose nuclear cardiology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physics, University of Trieste, Trieste 34127, Italy.
- Abdus Salam International Centre for Theoretical Physics (ICTP), Trieste 34151, Italy.
- Medical Physics and Radiation Protection Department, University Hospital Rijeka, Rijeka 51100, Croatia.
- Radiology Department, General Hospital Pula, Pula 52100, Croatia.
- School of Medicine, Public Health and Paediatrics Department, University of Torino, Torino 10100, Italy.
- Department of Medical Physics and Biophysics, Faculty of Medicine, University of Rijeka, Rijeka 51100, Croatia.
ORCID-Profile: Roberta Matheoud, Marco Brambilla
Zitieren
APA
Gomez Villegas, S., Dundara Debeljuh, D., Calcaterra, D., Pribanic, I., Leva, L., Garrou, F., D'Alessio, A., Matheoud, R., & Brambilla, M. (2026). Half-count myocardial imaging on the D-SPECT camera: phantom validation and clinical agreement for perfusion and function. British Journal of Radiology. https://doi.org/10.1093/bjr/tqag201
Vancouver
Gomez Villegas S, Dundara Debeljuh D, Calcaterra D, Pribanic I, Leva L, Garrou F, et al. Half-count myocardial imaging on the D-SPECT camera: phantom validation and clinical agreement for perfusion and function. British Journal of Radiology. 2026. doi:10.1093/bjr/tqag201
BibTeX
@article{GomezVillegas2026,
author = {Gomez Villegas, Sharon and Dundara Debeljuh, Dea and Calcaterra, Daniela and Pribanic, Ivan and Leva, Lucia and Garrou, Federico and D'Alessio, Andrea and Matheoud, Roberta and Brambilla, Marco},
title = {Half-count myocardial imaging on the D-SPECT camera: phantom validation and clinical agreement for perfusion and function},
journal = {British Journal of Radiology},
year = {2026},
doi = {10.1093/bjr/tqag201}
}
EUVIMED