EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting

Haechan J Yang iD, Nikolaj K G Jensen, Ben Beech, Stewart Gaede, Eugene Wong, Michael Lock

British Journal of Radiology · 01.09.2026 · 99 (1185) · 1902-1909

DOI: 10.1093/bjr/tqag132 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift British Journal of Radiology, online erschienen am 04.06.2026. Verfasst von Haechan J Yang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada. Hauptthemen laut MEDLINE: Liver Neoplasms, Contrast Media, Carcinoma, Hepatocellular, Four-Dimensional Computed Tomography. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

We compare the contrast-to-noise ratio (CNR) of tumors on 4D-CT and DCE-CT and explore how DCE-CT can be used to enhance tumor delineation for radiotherapy targeting.

Methods

A total of 18 intrahepatic lesions from 15 patients were included in this study. Eight patients with primary hepatocellular carcinoma, and 7 metastatic patients with a total of 10 tumors, underwent DCE-CT and respiration-tracked 4D-CT. Both 4D-CT and DCE-CT were acquired at 120 kVp, but with 600 and 1920 mAs, respectively. CNRs were calculated for each lesion in each image set and compared using a paired t-test.

Results

DCE-CT image sets had CNRs that were higher than those of 4D-CT image sets. The improvement in CNR was significant for lesions that were metastatic rather than primary, for lesions that were smaller than the mean size (5.7 cm), and for lesions that had undergone prior treatment rather than those that had not.

Conclusions

Target volume delineation in liver radiotherapy is challenging due to the inherent low tumor CNR. DCE-CT significantly improves CNR in liver metastases compared to 4D-CT, the current standard for radiation treatment planning. Considerations for DCE-CT include patients with metastatic lesions, additional iodinated contrast, and CT dose. Advances in knowledge DCE-CT combined with 4D-CT can offer advantages in delineating small, previously-treated metastatic tumors for radiotherapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver NeoplasmsContrast MediaCarcinoma, HepatocellularFour-Dimensional Computed TomographyTomography, X-Ray ComputedHumansFemaleMaleMiddle AgedAgedSignal-To-Noise RatioRespirationRadiotherapy Planning, Computer-Assisted

Stichwörter der Autor:innen

4D-CTcontrast-to-noise ratiodynamic contrast-enhanced CTliver tumorstumor delineation

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Schulich School of Medicine and Dentistry, Western University, London, ON N6A 3K7, Canada.
  • Department of Oncology, Rigshospitalet, Copenhagen University Hospital, 2100 Copenhagen, Denmark.
  • Physics & Engineering, Verspeeten Family Cancer Centre, London Health Sciences Centre, London, ON N6A 5W9, Canada.
  • Department of Physics & Astronomy, Western University, London, ON N6A 3K7, Canada.
  • Radiation Oncology, Verspeeten Family Cancer Centre, London Health Sciences Centre, London, ON N6A 5W9, Canada.
  • Department of Oncology, Western University, London, ON N6A 3K7, Canada.

ORCID-Profile: Haechan J Yang

Zitieren

APA

Yang, H. J., Jensen, N. K. G., Beech, B., Gaede, S., Wong, E., & Lock, M. (2026). A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting. British Journal of Radiology, 99(1185), 1902-1909. https://doi.org/10.1093/bjr/tqag132

Vancouver

Yang HJ, Jensen NKG, Beech B, Gaede S, Wong E, Lock M. A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting. British Journal of Radiology. 2026;99(1185):1902-1909. doi:10.1093/bjr/tqag132

BibTeX
@article{Yang2026,
  author = {Yang, Haechan J and Jensen, Nikolaj K G and Beech, Ben and Gaede, Stewart and Wong, Eugene and Lock, Michael},
  title = {A comparison of contrast-to-noise ratio of liver tumors between dynamic contrast-enhanced CT and respiration-tracked 4D-CT for radiotherapy targeting},
  journal = {British Journal of Radiology},
  year = {2026},
  volume = {99},
  number = {1185},
  pages = {1902--1909},
  doi = {10.1093/bjr/tqag132}
}
Kostenlos starten →