Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT
European Radiology · 2024
DOI: 10.1007/s00330-024-11204-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Radiology, 2024. Verfasst von Jinhua Wang und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical …. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Lung Neoplasms, Solitary Pulmonary Nodule, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: the National Natural Science Foundation of China, the National High Level Hospital Clinical Research Funding.
Abstract (Originalsprache)
PURPOSE: To investigate the image quality and the performance of photon-counting detector (PCD) CT compared to conventional energy-integrating detector (EID) CT in identifying subsolid nodule (SSN) characteristics. MATERIALS AND METHODS: Participants with SSNs who underwent same-day EID CT and PCD CT between October 2023 and April 2024 were prospectively included. The 1.0 mm EID CT images and, subsequently, 1.0 mm, 0.4 mm, and 0.2 mm PCD CT images were reviewed to assess image noise and subjective image quality on a 5-point Likert scale. SSN characteristics, including lobulation, spiculation, pleural retraction, air cavities, intra-nodular vessel signs, internal vascular changes, and heterogeneous solid components, were evaluated. Additionally, a step-by-step observation and comparison method was used to determine the presence of any additional characteristics. RESULTS: Forty-eight participants (mean age: 56 ± 11 years; 16 males) with 89 SSNs were included. PCD CT significantly reduced radiation dose when using matched scans (1.79 ± 0.39 vs 2.17 ± 0.57 mSv, p < 0.001). Compared to 1.0 mm EID CT, 1.0 mm PCD CT images exhibited significantly lower objective image noise and higher subjective image quality (all p < 0.001). Compared to EID CT, PCD CT demonstrated enhanced visualization of subtle characteristics, except for lobulation, with a 0.4 mm section thickness offering a favorable balance between ultra-high resolution and perceived image quality for radiologists. CONCLUSION: PCD CT facilitated radiation dose reduction and outperformed conventional EID CT in terms of image quality and visualization of SSN characteristics. KEY POINTS: Question PCD CT, featuring ultra-high-resolution mode acquisition and a thinner reconstruction, has not been fully explored for characterizing SSNs. Findings Compared to EID CT, PCD CT was associated with lower objective image noise, higher subjective image quality, and superior SSN characterization. Clinical relevance PCD CT effectively reduced the radiation dose delivered to the patients and enabled more precise SSN characterization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Department of Thoracic Surgery, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Department of Epidemiology and Health Statistics, Institute of Basic Medicine Sciences, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Theranostics and Translational Research Center, National Infrastructures for Translational Medicine, Institute of Clinical Medicine, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking…
- 4 + 4 Medical Doctor Program, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
- Siemens Healthineers Ltd CT Collaboration, Siemens Healthineers Ltd, Beijing, China.
Förderung
- the National Natural Science Foundation of China
- the National High Level Hospital Clinical Research Funding
Zitieren
APA
Wang, J., Huang, Z., Zhu, Z., Wang, B., Han, W., Hu, G., Ying, Z., Yu, Y., Wang, Y., Pan, Z., Wang, D., Song, Y., Li, H., Liu, L., Song, L., Liang, N., & Song, W. (2024). Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT. European Radiology. https://doi.org/10.1007/s00330-024-11204-6
Vancouver
Wang J, Huang Z, Zhu Z, Wang B, Han W, Hu G, et al. Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT. European Radiology. 2024. doi:10.1007/s00330-024-11204-6
BibTeX
@article{Wang2024,
author = {Wang, Jinhua and Huang, Zhicheng and Zhu, Zhenchen and Wang, Baiyu and Han, Wei and Hu, Ge and Ying, Zhoumeng and Yu, Yang and Wang, Yadong and Pan, Zhengsong and Wang, Daoyun and Song, Yang and Li, Haochen and Liu, Lei and Song, Lan and Liang, Naixin and Song, Wei},
title = {Photon-counting detector CT provides superior subsolid nodule characterization compared to same-day energy-integrating detector CT},
journal = {European Radiology},
year = {2024},
doi = {10.1007/s00330-024-11204-6}
}
EUVIMED