EUVIMEDEUVIMED entdecken
Validierungsstudie

Photon-counting CT Extracellular Volume Fraction for Liver Fibrosis Assessment: Validation against MR Elastography and Histopathology

Xinyu Wu iD, Jinzhe Li, Rong Deng iD, Xinxin Xu iD, Jiahao Zhou iD, Huanhuan Chong iD, Weixia Li iD, Peng Wu iD, Yongjun Chen, Yuchen Yang, Rui Chang, Haipeng Dong iD und 8 weitere

Radiology · 2026

DOI: 10.1148/radiol.253979 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Radiology, 2026. Verfasst von Xinyu Wu und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin 2nd Rd, Huangpu District, Shanghai 200025,…. Hauptthemen laut MEDLINE: Liver Cirrhosis, Elasticity Imaging Techniques, Tomography, X-Ray Computed, Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Extracellular volume fraction measured with photon-counting CT was used to accurately quantify liver fibrosis and enabled excellent stratification for fibrosis staging equivalent to MR elastography, using histopathologic findings as the reference.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver CirrhosisElasticity Imaging TechniquesTomography, X-Ray ComputedMagnetic Resonance ImagingHumansMaleMiddle AgedFemaleProspective StudiesAgedFeasibility StudiesLiverReproducibility of Results

Autor:innen und Institutionen

  • Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, No. 197 Ruijin 2nd Rd, Huangpu District, Shanghai 200025, China.
  • Faculty of Medical Imaging Technology, College of Health Science and Technology, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Philips Healthcare, Shanghai, China.
  • Department of General Surgery, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Department of Radiology, Charité - Universitätsmedizin Berlin, Berlin, Germany.
  • CT Collaboration, Siemens Healthineers, Shanghai, China.

ORCID-Profile: Xinyu Wu, Rong Deng, Xinxin Xu, Jiahao Zhou, Huanhuan Chong, Weixia Li, Peng Wu, Haipeng Dong, Ruokun Li, Ingolf Sack, Jing Guo, Zhihan Xu, Bernhard Schmidt, Amir A Borhani, Fuhua Yan, Huimin Lin

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Wu, X., Li, J., Deng, R., Xu, X., Zhou, J., Chong, H., Li, W., Wu, P., Chen, Y., Yang, Y., Chang, R., Dong, H., Li, R., Sack, I., Guo, J., Xu, Z., Schmidt, B., Borhani, A. A., Yan, F., & Lin, H. (2026). Photon-counting CT Extracellular Volume Fraction for Liver Fibrosis Assessment: Validation against MR Elastography and Histopathology. Radiology. https://doi.org/10.1148/radiol.253979

Vancouver

Wu X, Li J, Deng R, Xu X, Zhou J, Chong H, et al. Photon-counting CT Extracellular Volume Fraction for Liver Fibrosis Assessment: Validation against MR Elastography and Histopathology. Radiology. 2026. doi:10.1148/radiol.253979

BibTeX
@article{Wu2026,
  author = {Wu, Xinyu and Li, Jinzhe and Deng, Rong and Xu, Xinxin and Zhou, Jiahao and Chong, Huanhuan and Li, Weixia and Wu, Peng and Chen, Yongjun and Yang, Yuchen and Chang, Rui and Dong, Haipeng and Li, Ruokun and Sack, Ingolf and Guo, Jing and Xu, Zhihan and Schmidt, Bernhard and Borhani, Amir A and Yan, Fuhua and Lin, Huimin},
  title = {Photon-counting CT Extracellular Volume Fraction for Liver Fibrosis Assessment: Validation against MR Elastography and Histopathology},
  journal = {Radiology},
  year = {2026},
  doi = {10.1148/radiol.253979}
}
Kostenlos starten →