Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study
British Journal of Radiology · 01.03.2025 · 98 (1167) · 404-411
DOI: 10.1093/bjr/tqae233 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift British Journal of Radiology, online erschienen am 13.11.2024. Verfasst von Liwen Du und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Ultrasonography, Mammary, Clinical Competence, Radiologists. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
Objective
To compare the performance of radiologists when assisted by an S-detect system with that of radiologists or an S-detect system alone in diagnosing breast masses on US images in a dual-centre setting.
Methods
US images were retrospectively identified 296 breast masses (150 benign, 146 malignant) by investigators at 2 medical centres. Six radiologists from the 2 centres independently analysed the US images and classified each mass into categories 2-5. The radiologists then re-reviewed the images with the use of the S-detect system. The diagnostic value of radiologists alone, S-detect alone, and radiologists + S-detect were analysed and compared.
Results
Radiologists had significantly decreased the average false negative rate (FNR) for diagnosing breast masses using S-detect system (−10.7%) (P < .001) and increased the area under the receiver operating characteristic curve (AUC) from 0.743 to 0.788 (P < .001). Seventy-seven out of 888 US images from 6 radiologists in this study were changed positively (from false positive to true negative or from false negative to true positive) with the S-detect, whereas 39 out of 888 US images were altered negatively.
Conclusion
Radiologists had better performance for the diagnosis of malignant breast masses on US images with an S-detect system than without. Advances in knowledge The study reported an improvement in sensitivity and AUC particularly for low to intermediate-level radiologists, involved cases and radiologists from 2 different centres, and compared the diagnostic value of using S-detect system for masses of different sizes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China.
- Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China.
- Department of Ultrasound, The Affiliated Drum Tower Hospital, Medical School of Nanjing University, Nanjing 210008, China.
- Department of Ultrasound, Jiangsu Cancer Hospital, Nanjing 210009, China.
- Department of Ultrasound, Shanghai East Clinical Medical College, Nanjing Medical University, Nanjing 211166, China.
ORCID-Profile: Bo Zhang
Zitieren
APA
Du, L., Liu, H., Cai, M., Pan, J., Zha, H., Nie, C., Lin, M., Li, C., Zong, M., & Zhang, B. (2025). Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study. British Journal of Radiology, 98(1167), 404-411. https://doi.org/10.1093/bjr/tqae233
Vancouver
Du L, Liu H, Cai M, Pan J, Zha H, Nie C, et al. Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study. British Journal of Radiology. 2025;98(1167):404-411. doi:10.1093/bjr/tqae233
BibTeX
@article{Du2025,
author = {Du, Liwen and Liu, Hongli and Cai, Mengjun and Pan, Jiazhen and Zha, Hailing and Nie, Chenlei and Lin, Minjia and Li, Cuiying and Zong, Min and Zhang, Bo},
title = {Ultrasound S-detect system can improve diagnostic performance of less experienced radiologists in differentiating breast masses: a retrospective dual-centre study},
journal = {British Journal of Radiology},
year = {2025},
volume = {98},
number = {1167},
pages = {404--411},
doi = {10.1093/bjr/tqae233}
}
EUVIMED