Ultrasound Inversion Imaging Improves the Specificity of BI ‐ RADS Category 4A Masses, Especially in Masses Without Calcification. A Single‐Center Experience
Journal of Clinical Ultrasound · 2025
DOI: 10.1002/jcu.24077 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Jiajia Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, China. Hauptthemen laut MEDLINE: Breast Neoplasms, Ultrasonography, Mammary. Die Arbeit nennt 27 Literaturangaben. Gefördert von: university research project of Anhui province, Anhui Province clinical medical research transformation project, clinical research key project and general project, the Second Affiliated Hospital of Anhui Medical University.
Abstract (Originalsprache)
Objective
This study aimed to assess whether ultrasound inversion imaging enhances the specificity of Breast Imaging Reporting and Data System (BI‐RADS) BI‐RADS 4A masses, reducing unnecessary biopsies.
Method
From July 2021 to March 2023, 425 pathologically confirmed breast masses were collected from the Second Affiliated Hospital of Anhui Medical University. Based on a five‐point scale of inversion imaging criteria proposed in a previous study, the diagnostic performance of three classification algorithms, including BI‐RADS, BI‐RADS category after inversion imaging, and BI‐RADS category after inversion imaging without calcification masses—via receiver operating characteristic (ROC) curve analysis.
Results
Among the 425 breast masses, 116 masses were classified as BI‐RADS category 4A (82 benign, 34 malignant). After inversion imaging, 74 benign BI‐RADS category 4A masses were correctly downgraded to BI‐RADS category 3, avoiding biopsies. ROC curve values indicated that the specificity, sensitivity, and accuracy were 31.06%, 98.48%, and 72.94%, respectively, with BI‐RADS, 72.05%, 95.83%, and 86.82%, respectively, with BI‐RADS after inversion imaging, and 86.51%, 97.75%, and 93.09%, respectively, with BI‐RADS category after inversion imaging without calcification masses.
Conclusion
Ultrasound inversion imaging offers a feasible supplementary method to distinguish between benign and malignant breast masses, improving BI‐RADS 4A specificity, especially for non‐calcified masses.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
- Department of Thyroid and Breast Surgery, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
ORCID-Profile: Jiajia Wang
Förderung
- university research project of Anhui province
- Anhui Province clinical medical research transformation project
- clinical research key project and general project, the Second Affiliated Hospital of Anhui Medical University
Zitieren
APA
Wang, J., Zhan, Y., Bi, Y., Wu, X., Li, R., Gu, Y., Gao, L., Tang, T., & Peng, M. (2025). Ultrasound Inversion Imaging Improves the Specificity of BI ‐ RADS Category 4A Masses, Especially in Masses Without Calcification. A Single‐Center Experience. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24077
Vancouver
Wang J, Zhan Y, Bi Y, Wu X, Li R, Gu Y, et al. Ultrasound Inversion Imaging Improves the Specificity of BI ‐ RADS Category 4A Masses, Especially in Masses Without Calcification. A Single‐Center Experience. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24077
BibTeX
@article{Wang2025,
author = {Wang, Jiajia and Zhan, Yunyun and Bi, Yu and Wu, Xiabi and Li, Rubing and Gu, Yunxin and Gao, Lan and Tang, Tong and Peng, Mei},
title = {Ultrasound Inversion Imaging Improves the Specificity of BI ‐ RADS Category 4A Masses, Especially in Masses Without Calcification. A Single‐Center Experience},
journal = {Journal of Clinical Ultrasound},
year = {2025},
doi = {10.1002/jcu.24077}
}
EUVIMED