EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of adaptive imaging receiver coil and traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging of the liver

Lingrong Peng iD, Qilong Chen, Zhanao Meng, Yao Zhang, Jin Wang, Huiquan Wen

British Journal of Radiology · 01.11.2024 · 97 (1163) · 1826-1832

DOI: 10.1093/bjr/tqae163 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift British Journal of Radiology, online erschienen am 21.08.2024. Verfasst von Lingrong Peng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The Third Affiliated Hospital of Sun Yat-Sen University (SYSU), Guangzhou 510630, China. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Signal-To-Noise Ratio, Liver Neoplasms, Liver. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Program of Guangzhou, Clinical Research Foundation of the 3rd Affiliated Hospital of Sun Yat-Sen University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To compare the image quality and efficacy of the adaptive imaging receiver (AIR) coil (GE Healthcare) and the traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging (MUSE-DWI) in the detection of focal liver lesions (FLLs).

Methods

Two groups of MUSE-DWI were obtained. Image quality was qualitatively evaluated by 3 independent blinded radiologists on a 5-point scale, and quantitative parameters were calculated by measurements of the region of interest in the liver and FLLs. McNemar’s test were used to compare the characteristics and detectability.

Results

Less image noise, sharper contours, milder susceptibility artefacts, and better liver lesion conspicuity were found by all radiologists in 60 livers with 140 FLLs with the AIR coil than with the traditional coil (reader average mean, 4.3-4.4 vs. 3.7-4.0, P < .001). The signal-to-noise ratio (SNR) of the liver was significantly higher with the AIR coil than with the traditional coil (right lobe: mean, 8.89 vs.7.76, P < .05; left lobe: mean, 7.14 vs.6.19, P < .001), and the SNR of FLLs (mean, 24.62 vs. 21.01, P < .001) and lesion-to-liver CNR (mean, 16.61 vs. 14.02, P < .001) exhibited significant differences between the AIR coil and the traditional coil. Besides, superior detection of FLLs was observed with the AIR coil compared to the traditional coil (95.7% [134/140] vs. 85.7% [120/140], P < .001).

Conclusions

The AIR coil yields less noise, fewer distortions, better lesion detectability, higher SNR of the liver and FLLs, and improved lesion-to-liver CNR during liver MUSE-DWI. Thus, it is a feasible and effective scanning scheme in liver MRI. Advances in knowledge The AIR coil improves SNR and the quality of liver MR imaging compared with the traditional coil.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingSignal-To-Noise RatioLiver NeoplasmsLiverHumansFemaleMaleMiddle AgedAdultAgedLiver Diseases

Stichwörter der Autor:innen

Adaptive imaging receiver coilComparative studyDiffusion weighted imagingMagnetic resonance imagingSignalto-noise ratio

Autor:innen und Institutionen

  • Department of Radiology, The Third Affiliated Hospital of Sun Yat-Sen University (SYSU), Guangzhou 510630, China.

ORCID-Profile: Lingrong Peng

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Program of Guangzhou
  • Clinical Research Foundation of the 3rd Affiliated Hospital of Sun Yat-Sen University

Zitieren

APA

Peng, L., Chen, Q., Meng, Z., Zhang, Y., Wang, J., & Wen, H. (2024). Comparison of adaptive imaging receiver coil and traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging of the liver. British Journal of Radiology, 97(1163), 1826-1832. https://doi.org/10.1093/bjr/tqae163

Vancouver

Peng L, Chen Q, Meng Z, Zhang Y, Wang J, Wen H. Comparison of adaptive imaging receiver coil and traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging of the liver. British Journal of Radiology. 2024;97(1163):1826-1832. doi:10.1093/bjr/tqae163

BibTeX
@article{Peng2024,
  author = {Peng, Lingrong and Chen, Qilong and Meng, Zhanao and Zhang, Yao and Wang, Jin and Wen, Huiquan},
  title = {Comparison of adaptive imaging receiver coil and traditional coil for multiplexed sensitivity encoding diffusion-weighted imaging of the liver},
  journal = {British Journal of Radiology},
  year = {2024},
  volume = {97},
  number = {1163},
  pages = {1826--1832},
  doi = {10.1093/bjr/tqae163}
}
Kostenlos starten →