Improving lipid identification and quantification: chromatogram deconvolution for LC-MS/MS workflows
Bioinformatics · 2026
DOI: 10.1093/bioinformatics/btag695 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinformatics, 2026. Verfasst von Felix Niedermaier und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Währinger Straße 38-42, 1090 Vienna, Vienna, Austria. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Lipids, Lipidomics, Liquid Chromatography-Mass Spectrometry. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bundesministerium für Bildung, Wissenschaft und Forschung.
Abstract (Originalsprache)
Motivation Lipidomics relies on mass spectrometry-based workflows to identify and quantify complex lipid species. Due to the modular architecture of lipids, including headgroups, backbones, and fatty acyl chains, distinct precursor ions often produce isobaric or identical fragment ions. This problem is amplified in data-independent acquisition (DIA), where wide isolation windows (e.g. 25 Da) allow co-eluting precursors with different m/z values to generate highly chimeric MS/MS spectra. Consequently, fragments originating from multiple precursors, including isobars, isomers, and lipid-class-specific ions, are merged into a single MS/MS spectrum. Current lipid identification strategies often process such chimeric spectra in an uncontrolled manner, assigning them to one or more candidate lipids, thereby increasing false-positive identifications. Results Here, we introduce an algorithm that deconvolutes chimeric MS/MS spectra and chromatograms by exploiting their temporal correlation with associated precursor chromatographic profiles, independent of elution peak shape. Using simulated and real experimental lipidomics data, we demonstrate that this approach substantially improves lipid fragment assignment, reduces false-positive identifications, and enables more reliable fragment-level quantification, leading to more robust downstream statistical analyses and biological interpretations. Availability and Implementation Source code of the software library: GitLab (Apache 2.0 License): https://gitlab.com/computational-multiomics/projects/mixture-model-deconvolution; Data: Zenodo (Apache 2.0 License): https://doi.org/10.5281/zenodo.21218594.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Analytical Chemistry, Faculty of Chemistry, University of Vienna, Währinger Straße 38-42, 1090 Vienna, Vienna, Austria.
- Vienna Doctoral School in Chemistry (DoSChem), University of Vienna, Währinger Straße 42, 1090 Vienna, Vienna, Austria.
ORCID-Profile: Felix Niedermaier, Denise Wolrab-Frühauf, Robert Ahrends, Dominik Kopczynski
Förderung
- Bundesministerium für Bildung, Wissenschaft und Forschung
Zitieren
APA
Niedermaier, F., Wolrab-Frühauf, D., Ahrends, R., & Kopczynski, D. (2026). Improving lipid identification and quantification: chromatogram deconvolution for LC-MS/MS workflows. Bioinformatics. https://doi.org/10.1093/bioinformatics/btag695
Vancouver
Niedermaier F, Wolrab-Frühauf D, Ahrends R, Kopczynski D. Improving lipid identification and quantification: chromatogram deconvolution for LC-MS/MS workflows. Bioinformatics. 2026. doi:10.1093/bioinformatics/btag695
BibTeX
@article{Niedermaier2026,
author = {Niedermaier, Felix and Wolrab-Frühauf, Denise and Ahrends, Robert and Kopczynski, Dominik},
title = {Improving lipid identification and quantification: chromatogram deconvolution for LC-MS/MS workflows},
journal = {Bioinformatics},
year = {2026},
doi = {10.1093/bioinformatics/btag695}
}
EUVIMED